HEINRICH DVA8-500 Installation And Operation Manual Download Page 1

DVA8-500

DVA8-500RT

DVA8-500RM

DVA8-500SF

HEINRICH

Technology beyond imagination

I N S T A L L A T I O N   A N D   O P E R A T I O N  

M A N U A L

Summary of Contents for DVA8-500

Page 1: ...DVA8 500 DVA8 500RT DVA8 500RM DVA8 500SF HEINRICH Technology beyond imagination INSTALLATION AND OPERATION MANUAL...

Page 2: ...16 4 3 Auto Broadcast Emergency Message 16 4 4 Sosftware DVA8 500SF Setting 16 4 5 Emergency Fireman Microphone Operation 16 4 6 Remote Paging Microphone DVA8 500RM Operation 16 17 5 Software DVA8 50...

Page 3: ...vacuate standard Usually used in must small system which need voice evacuation or system that only need one call channel Features Meet the requirements of GB16806 2006 standard and European voice alar...

Page 4: ...the host DVA6 500 will not auto standby to backup amplifier without soft ware correct configuration 8 zone speaker outputs each zone max power output is 500W total 8 zone power output max is 500W Wit...

Page 5: ...adcast will be activated by the trigger inputs on the rear panel of host and extension unit and red light flashing Reset the Emergency Mode a Press the ACK Reset button on the front panel to exist the...

Page 6: ...a resistance to proofread before obtaining the loop impedance value of the current speaker please follow below steps Unplug the host back row ID switch 7 Until hear buzzer sing alternately or see pane...

Page 7: ...man microphone of priority 20 Monitor Speaker Attenuator Increase or decrease the built in monitor speaker loudness 21 Emergency Microphone Gain Control It is used to adjust the emergency microphone i...

Page 8: ...y Outputs For 4 wired volume control each zone rated output current is 0 2A max total six zone outputs less than 28W 3 Six A B Speaker Zone Outputs Direct connection of 100V loudspeakers or 3 wire vol...

Page 9: ...uter opened up the DHCP function 4 Support PC software directly connection to DVA8 500 automatic identify cross and straight cable All communication cable shall be meet TIE EIA 568B standards includin...

Page 10: ...standby amplifier will be auto switched in service once the main amplifier have faulty the standby amplifier power shall be same watts or higher watts than the main amplifier The standby amplifier co...

Page 11: ...eaker line supervision function 16 External Two Microphone or Balanced Line Inputs 5 6 17 Gain Control These gain control is used to increase or decrease the input sensitivity for MIC Line inputs 5 6...

Page 12: ...t Closed circuit no voltage DVA6State Output Closed circuit no voltage DVA6Reset Input Closed circuit no voltage T 0 5s 8 Program Control Output Closed circuit no voltage 8 Program Control Input Way 1...

Page 13: ...e real time monitored by the system Feature Easy intuitive and user friendly operation paging console Configurable PPT paging mode and normal paging mode With 9 levels of configurable priority Support...

Page 14: ...terminate the zone paging or add the zone paging 5 All Zone Selector Select or deselect all zones and the indicator will be illuminated or extinguished accordingly Button program to include some zone...

Page 15: ...king Environment Operation Temp 5 40 Storage Temp 20 70 Relative Humidity 95 Mechanical Part Dimension 240 W x 140 D x 55 H mm Weight 1kg Finish Aluminum case in black 11 ID Configuration Dipswitch Up...

Page 16: ...line input1 6 on rear panel select the line input HEINRICH System Connection Example DVA8 500 DVA8 500SFT DVA8 500RT x 01 DVA8 500RT x M DPA500 DPA500 DPA500 NOTE 1 Redundant cable 2 CAT 5 STP UTP cab...

Page 17: ...ontrol system for inter action There are two kinds of control inputs by short circuit contact or by level mode Press again the emergency button or remote reset input to terminate the emergency broadca...

Page 18: ...HEINRICH...

Page 19: ...rent zone is prohibited for operation Current Zone is working Zone impedance vibration open circuit or short circuit The current zone is normal no broadcast The current zone is under emergency broadca...

Page 20: ...are install or will have trouble after it Before that please check you have administration authority or not and the method as below Click on the icon DVA8 exe by right mouse to select the properties t...

Page 21: ...operation page of the software Click on to enter user name password for identity verification The software will be auto exist once 3 times wrong password input Synchronize The first connection of DVA...

Page 22: ...king the working status of system s device module 2 SYSTEM CONFIGURATION for check or modify the working device data in current system 3 LOG is for checking data record of system device and module 4 O...

Page 23: ...ter modify please make sure to click Application after modify The red LED on the top right can only reset via the red EMERGENCY button on the front panel of DVA8 500 or 3 Emergency Reset Input in rear...

Page 24: ...ystem zones control for sure it will be the same result if you put all the system zones to one group or multi groups Choose the target zone Click all zones then choose output audio Click DVA8 MESSAGE...

Page 25: ...words system detects the impendence is more than 10 30 of the spe aker first time system building base on can not designate error to single device or designated zone or cable is disconnect between de...

Page 26: ...e drop down list box which at the right of Host number 1 20 to set the number of host and extension host number System must set one host if ho st nu mber is more than one and v button on the right of...

Page 27: ...aging prompt tone switch to set the switch and designate warning tone of each microphone the way is the same as DVA8 microphone above You can set more microphone by click to change User can set differ...

Page 28: ...e message User can set delay time of executing fire alarm via Delay start time 0 300S please note the unit is second if 0 means no delay and execute at once Digital Voice Type is to choose type of DVA...

Page 29: ...dialog box show current zone number Left part is current zone list choose and add to the right means add the zone in current group you can double click corresponding zone or though Shift and Ctrl but...

Page 30: ...t of the output permission of current audio please be careful when modifying the above figure is default settings of this system Instruction 1 User can on line or off line to set the system parameter...

Page 31: ...ils of current log Description User can check designated time recording though Log type and and click on tooling bar to save the log as excel sheet 1 1 1 1 OTHER 1 Change password 2 Correct system tim...

Page 32: ...f it is wrong report can rise the percentage preperly Attention 1 Don t put the system device installed in direct sunlight or near the heating element because the device may fade deformation or stop w...

Page 33: ...configuration accordingly to your requirements If major fault cause system not working please contact our After Sales Service for Repair processing Built in accessories Do not dismantle machine withou...