41
X. CONTROL PANEL
USING THE CONTROL PANEL
KEY OPERATION:
A.
Temperature control of fridge compartment
B.
Power cool/Locking / Unlocking
OPERATING CONDITION:
1.
The control panel is 100% lit up for 3 seconds, which operates exactly as per the
setting (mode and temperature) before the power off. The system will be
automatically locked 2 seconds after the last key operation. After locking, the light
of the panel would be off 1 minute after the last key operation.
2.
Both preset temperatures of fridge compartment would be shown on the display.
DISPLAY
1.
The panel will be lit up once the door of fridge compartment or freezer
compartment is opened. (one door signal is sensed at a time)
2.
The panel will be lit up by any key operation whereas the light would be off 1
minute after the last operation. Display during normal operation.
3.
Temperature Display of the Fridge Compartment: Indicating the temperature of the
current setting.
LOCK ICON
–
Temperature control of the fridge compartment
This key is workable both in User Defined mode as well as Power Cool Mode. After
entering the temperature control of the fridge compartment, this key flashes. By
touching the key consecutively, the temperature would change in a circle of `2
˚
C, `3
˚
C,
`4
˚
C, `6
˚
C, `8
˚
C after which 5 seconds flashing means the selection of temperature is
settled.