Instruction manual / EasyGrinder
13
7 Emery setting procedure
1. Take off the disc guard.
2. Remove the used up or damaged emery paper carefully and without any
aggressive equipment off the disc.
3. Clean the disc of glue and other contamination.
NOTE
: Do not use any form of petroleum based solvents when cleaning discs.
4. Ensure disc is dry and completely free from any foreign matter. If necessary clean
disc only with warm soapy water and a scrubbing brush, allow to dry.
5. Place the centering bush on the fixation flange of the disc.
6. Take a new original Heiniger emery paper and take off the protective film.
7. Put the new emery papier by the glue side inside, on the fitted centering bush,
on the cleaned grinding disc.
8. Pat the emery papier firmly with the flat hand evenly on the disc.
NOTE
:
No adhesion of the disc at under 5° Celsius and when the emery paper
has been stored at frost temperature.
9. Control the whole surface of the emery paper for bubbles and consistency of
the adhesion. Therefore, pat the surface with the back of the finger and observe
the sound for irregularities.
NOTE
: Treat the disc and emery paper very carefully.
10. The disc is now ready to grind.
8 Maintenance
Use only genuine replacement parts. All parts are available through Heiniger dealers.
Use only qualified personnel for electrical repairs. Always contact an authorized
service centre if you are unsure how to rectify a problem or in case of any malfunctions
not being contained in this manual. Only perform maintenance when the grinder is
disconnected from the power.
Motor
Failure to keep the motor dust free may reduce the cooling ability of the motor and
cause it to cut out due to overheating. Periodically check the condition of the power
cord, replace if worn or damaged.
Rubber feet
Ensure that feet are fitted and secure; failure to do so may lead to the grinder
becoming dangerously unstable.
Switch
Replace damaged switches immediately.
Pendulum hook
If the pendulum hook is damaged replace it before the grinder is used.
Pendulum upright
Control the pendulum upright everytime before use for fixed fitting.