11
Note!
File the replacing instructions in the technical documentation of the machine
and record the changes!
Tests after mounting the new motor QAN 200U
According to DIN VDE 0113, part 1 / EN 60204-1 the following must be checked after a
component has been exchanged:
1. Check whether the electrical equipment corresponds to the technical documentation.
2. Check whether the connections of the grounding conductor system are continuous.
3. Perform a functional test.
DIN VDE 0113, part 1 / EN 60204-1