1. Press the EMERGENCY STOP button.
2. Restart/reboot the control.
®
The log-on window of Windowx XP is displayed.
3. Click "TNC User".
®
The control restarts.
4. Press the Windows key to display the taskbar.
5. Open the path "My Computer/Local Disk (C:)/Program Files/NCSW/ ...
6. Select the NC software version, e.g. "340492-005_SP7".
7. Start the setup.
®
The window "Install Program As Other User" appears.
8. Select OEM in the "Username:" input field and enter the password.
9. Confirm the entry with "OK".
®
The "iTNC 530 Software Update" menu is displayed.
10. Follow the on-screen instructions. (The control restarts after the installation.)
11. Click "TNC User" in the log-on window of Windows XP.
®
The control starts up.
12. Delete the displayed MPNAME.MP.
®
An adapted MPNAME.MP is created.
13. Check whether the NC software version, e.g. "340492 05 SP7" (or "340493 05 SP7") is correct.
Installing the NC software 340492-05 SP7, -06 SP9, -07 SP11, -08 SP3 and higher
(or 340493-05 SP7, -06 SP9, -07 SP11, -08 SP3 and higher) with Windows XPe
Note!
Local administrator rights are required to install NC software.
If necessary, contact the machine tool builder!
Windows knowledge is required.