28
16. Press the "MOD" key.
17. Press the "UPDATE DATA" soft key.
18. Convert the data from ASCII to BINARY format (press the corresponding soft key).
Load the associated service pack:
19. Press the "SP -> iTNC" soft key.
®
A pop-up window is displayed.
20. In the upper part of the window, place the cursor on the C partition of the hard disk.
21. Open the directory tree by pressing "+/-".
22. Open the directory C:\Program Files\NCSW\...
23. Place the cursor on the folder "340492_001_SP2" (or "340493_001_SP2").
24. Press the "ENT" key.
®
The file "340492.001 SP2" (or "340493.001 SP2") is shown in the lower part
of the window.
25. Press the "FILES" soft key.
®
The cursor jumps to the lower part of the window.
26. Press the "SELECT" soft key.
®
The service pack is copied from the C partition to the
SYS partition and installed then.
27. Check whether the NC software version "340492 01 SP2" (or "340493 01 SP2") is correct
.