Gas fired igniter ZT0
Specifications
- 18 -
Status: 11-2018
4.2
Gas fired igniter
Characteristic
Value
Heat release
max. 120 kW
Flame length (depending on the gas)
max. 600 mm
Outer tube length
in 10 mm increments from
– to
240 - 15000 mm
Outer tube diameter
Outer tube length up to 4000 mm
Outer tube length from 4000 mm
dia. 48 mm
dia. 50 mm
For the stainless steel version always dia. 50 mm
Design pressure gas flange
max. 10 bar
Gas port
Rp ½, left or right
Maximum counter pressure in gas fired igniter
housing
200 mbarg overpressure
Air port
Rp 1, rotatable 4 x 90°
Air volume
max. 50 m³/h
Air temperature
max. 80 °C
Relative humidity
max. 70 %
Air quality
free of dust, oil, grease and aerosols
Air coefficient
The remaining air volume must be made available
in the combustion chamber.
0.3 - 0.5
Maximum ambient temperature of the outer tube
see chapter “Installation and electrical connection”
Total weight (depending on scope of delivery)
approx. 2.5 kg power head with mounting
approx. 3.5 kg/m (length of outer tube in cm, as
indicated in the rating plate)
Total dimensions (depending on scope of delivery)
Length of power head with mounting flange (see
dimensional drawing in section 4.4) + outer tube
length (in cm, as indicated in the rating plate)