HP105 Plasma arc voltage height controller
第
- 7 -
页 共
23
页
下降
起弧测试
自动
起弧
电源
反馈 碰撞
Manually
确认
Function Description:
LCD: display the working status and parameters.
Manual: Auto / Manual mode selection increase, alternating work.
Arc test: standby press, arcing into the test mode.
When arcing test, press to return to standby mode.
Menu: In standby mode press to enter the parameter setting mode.
When the parameter setting Press to return to standby.
Confirmation: parameter setting mode, confirm that the set
parameters.
Rise / fall: In standby mode, manual lifting torch.
When parameter setting, subtraction parameter values.
2.5
parameter settings