cable.
The sensor is mounted on the torch and that the torch nozzle is positioned in the
middle of the ring.
The following parts are connected to the protective conductor bus: machine earth
ground (GND).torch table and ground screw on HF100 using a cable with a
cross-section of 14 AWG (2.5 mm2).
2.
First, set on Manual mode, lift torch up over 20mm against steel plate.
3.
Turn the SENSITIVITY and DISTANCE in the middle position.
4.
Press Auto Test button to turn Auto on, if torch lift down, means Auto Height
is too low, then adjust RP4 clockwise to raise the auto height. If torch lift up, means
Auto height is too high, turn anti-clockwise.
Please protect the adjust Resistor to avoid damage, Do Not exceed 1/4 round on
every turn, and make record of turn direction.
5.
Attach the control box to the back panel and secure with four (4) screws.
6.
Configure the clearance distance and sensitivity.