HF100
CapecitanceHeightControler
http://www.heavth.com
第
- 10 -
页
共
14
页
Collision Signal Connection
3.1.2 SPEED CONTROLLER CLOCK FREQUENCY AND MAXIMUM MOTOR CURRENT
Use the toggle switches on DIP switch SP2 to configure the speed
controller clock frequency and maximum lifter motor current value.
Setting Toggle Switch 1 of DIP Switch SP2
:
Switch:
To the ON position
To the OFF position
1
18KHz
9KHz
Setting the controller clock frequency to 18 kHz requires that you take the
proper shielding and grounding precautions when running the lines to the lifter
motor. Following the proper wiring precautions ensures that the permissible
noise field intensity is not exceeded.
Using a controller clock frequency of 9 kHz meets the 10 kHz interference
suppression restrictions;however a whistling noise may be heard.
The position of toggle switches 2, 3 and 4 on DIP switch SP2 determine the
maximum current for the lifter motor.
To determine the correct amperage maximum value for the lifter motor,
refer to the lifter motor rating plate or the instruction manual that accompanied
the motor. Then, refer to Table I to set the toggle switches for DIP
Setting Toggle Switches 2, 3 and 4 of DIP Switch SP2
Set the toggle switches to this position:
Switch 2
Switch 3
Switch 4
maximum
current
:
OFF
OFF
OFF
4A
OFF
OFF
ON
3A
OFF
ON
ON
2A
ON
ON
ON
1A
HF100
Collision
Signal
COM
DC
POWER
CNC
X1
7
3
R
EL
AY
24V
+24V
0V