VICTORIA ROAD, AVONMOUTH, BRISTOL, BS11 9DB 

WEBSITE: www.heatstore.co.uk 

 

We offer a technical advisory service to installers and other customers with problems in 

the field. RING: “0117 923 5375” or E-MAIL: “[email protected]” 

GUARANTEE 

 

 

We, Heatstore, guarantee this product for a period of 24 months from the date of purchase. 

 

Within the guarantee period we will resolve, 

free of charge

, any manufacturing defects in the product 

resulting from faulty workmanship or material on condition that:- 

 

a)

 

The product has been correctly installed and commissioned in accordance with our instructions and    

is being used on the supply circuit or voltage printed on the rating plate. 

 

b)

 

The product has been used in accordance with these instructions and has not been tampered with  

or otherwise subject to misuse, neglect or accident. 

 

c)

 

The product has not been taken apart, modified or repaired except by a person authorised by us.

 

 

d)

 

Evidence of the date of purchase in the form of an invoice or receipt will be required in order to 

qualify under the terms of this guarantee. 

 

e)

 

For the service work to be undertaken free of charge, the work must only be undertaken by              

Heatstore, or our approved agents. 

 

f)

 

Service under guarantee has no effect on the expiry date.                                                                      

The guarantee on any exchanged parts or product ends when the original guarantee period ends. 

 

EXCLUSIONS 

 

This guarantee 

DOES NOT 

cover damage or defects arising from poor or incorrect installation, 

improper use or lack of maintenance, including the build-up of limescale.                                                           
The unit MUST NOT be fitted to any type of thermostatic mixer valve or tap. 

The unit MUST NOT be fitted to a bath or kitchen sink other than for hand-washing purposes 

It is the responsibility of the installer to check that the installation parameters meet the requirements              

of the products, and any relevant regulations. 

 

If we are called out to a fault, which is subsequently identified as being an installation fault, we will 

make a charge, it is important that the routine checks are completed before calling us out, as many 

issues can be simply diagnosed and resolved. 

A charge will be made where a call under the terms of the guarantee has been booked and a failure 

was not product related, or an engineer arrives and is not able to gain access. 

 

We make no guarantees as to response time for repairs. 

We will endeavour to achieve the most timely response possible but while we indicate an average 
response time, this should not be taken as a guarantee. 

 

The guarantee applies to a repair or replacement (at our discretion) of the product subject to the 

conditions above, and 

DOES NOT

 cover compensation for the loss of the product or consequential                         

loss of any kind. 

 

This guarantee does not apply to the repair or replacement of pressure relief devices, sprayheads, 

hoses, accessories, isolating switches, electrical cable, fuses and/or circuit breakers. 

 

This guarantee does not affect your statutory rights. 

 

 

 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 

 
 
 
 

 

 

 

GUARANTEE AND CONTACT DETAILS 

(A4) Leaflet No. 579-2152-30c 

Summary of Contents for Multiflow 10.8kW

Page 1: ...h the user after installation and demonstration It should be kept in a safe place as you may need to refer to it for general instructions or future maintenance HEATSTORE MULTIFLOW UNVENTED INSTANTANEOUS WATER HEATER Installation and User Guide ...

Page 2: ... the current edition of BS 7671 the IEE Wiring Regulations and Part P of the Building Regulations in force at the time of installation Installations outside England and Wales must also conform to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply Ensure that the mains water supply m...

Page 3: ...namic Water Pressure Basin Shower Minimum Maximum Minimum Maximum Up to 9 5kW 10 psi 0 7 bar 69 kPa 150 psi 10 3 bar 1035 kPa 15 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa Up to 10 8kW 15 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa 20 psi 1 4 bar 138 kPa 150 psi 10 3 bar 1035 kPa Up to 12 0kW 20 psi 1 4 bar 138 kPa 150 psi 10 3 bar 1035 kPa 25 psi 1 8 bar 172 kPa 150 psi 10 3 bar 1035 kPa FIX...

Page 4: ... the backplate diagram 3 Feed the cable through the grommet before you fix the unit to the wall Fixing to the wall Undo the retaining nuts and take the front cover off the unit Hold the backplate in position against the wall whilst you mark the four fixing holes Drill the holes and fix the unit to the wall using the screws supplied Plumbing the unit WARNING IF A NON RETURN VALVE IS FITTED IN THE I...

Page 5: ...Connecting the unit to the pipes The inlet and outlet are clearly marked on the unit They each have a Ø15mm straight shank connections The unit comes with a service valve diagram 5 which should be fitted on the inlet of the unit The valve can be used to turn off the water supply to the unit if it needs servicing or to reduce the main supply flow if it is too high Fitting the attachments If the uni...

Page 6: ... 6 point X to X to enable 10mm and 16mm to be correctly installed No cutting is required for 6mm cable In all cases the outer sheath of the cable MUST project through the grommet diagram 6 if side entry is used This will prevent water getting into the unit Strip back the insulation on the LIVE brown or red and NEUTRAL blue or black mains wires about 8mm Strip back any insulation on the EARTH green...

Page 7: ...on light goes out then turn it back until the neon just comes on check the water temperature at the handset and if necessary turn the cold tap on and adjust to get the desired shower temperature WARNING YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR AND DAMAGE REPLACE IF NECESSARY OR EVERY TWO YEARS WITH OUR APPROVED PART WARNING IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST DE...

Page 8: ...shed do not switch off the power if you are going to use the unit again shortly Shower Check that the power is switched on at the mains local isolator switch Turn on the hot or flow tap FULLY diagram 9 If the unit has been used recently run the water through for a few seconds to let the temperature settle down we advise you DO NOT enter the water flow during this time WARNING YOU MAY INITIALLY GET...

Page 9: ... the thermal cut out is operating A second outlet has been turned on Increase the supply water flow Make sure that the service valve is correctly adjusted Do not use the basin whilst using the shower Shower spray pattern deteriorates The shower handset is clogged Clean the handset using a descaling solution if required see page 9 We offer a technical advisory service on the telephone to installers...

Page 10: ...n supply to the INLET marked in blue Use a pump to boost the supply from a storage tank Reset it by opening the unit and pushing the button on the cut out diagram 11 Before you do this you must remove the cause of the problem Contact Heatstore Water too cold neon light on The power select screw is set to LO One element is not working The Power Supply Voltage has dropped Change the power select scr...

Page 11: ...s means that with the 12 0kW unit you can shower at 39 C with a flow rate of 5 litres minute in the middle of winter The unit includes a dual thermal cut out diagram 11 which is attached to the heat exchanger tube It will switch off the heater elements if the water flow is reduced too much and the temperature goes above a set limit The first stage cut out is cyclic and will automatically reset as ...

Page 12: ... NOT cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance including the build up of limescale The unit MUST NOT be fitted to any type of thermostatic mixer valve or tap The unit MUST NOT be fitted to a bath or kitchen sink other than for hand washing purposes It is the responsibility of the installer to check that the installation parameters meet ...