WHAT TO DO IF THINGS GO WRONG (2) 

 

 
PROFESSIONAL SERVICE 

 

If the previous “Self Help” checks fail to restore the performance, you should seek professional help. 

 

The person who installed the shower is probably the best one to investigate and correct it and is 
certainly the person to contact if you have had a problem in the guarantee period. 

 

The following additional checklist is provided for the benefit of the qualified service person. 

 

WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR                                           

BEFORE REMOVING THE COVER TO MAKE CHECKS 

 

Symptom 

Cause 

What to do 

Little or no water flows 

- neon light off 

The water pressure is very low. 

Use a pump to boost the supply from 

a storage tank.  

Cold water only 

- neon light off  

The main water is connected to 

the OUTLET of the unit. 

 

The water pressure is too low. 
 

 

The thermal cut-out has 
triggered. 
 

 
 

 

The flow switch is not working. 

Reconnect the main supply to the 

INLET (marked in blue). 

 

Use a pump to boost the supply from 
a storage tank. 

 

Reset it by opening the unit and 
pushing the button on the cut-out 
(diagram 11).  Before you do this you 

must remove the cause of the 
problem 

 

Contact Heatstore. 

Water too cold 
- neon light on 

The power select screw is set to 
“LO”. 

 

One element is not working. 
 

 
 
 

 
 

 

The Power Supply Voltage has 
dropped. 

Change the power select screw to 
"HI” (diagram 7). 

 

Switch off the electricity supply and 
check the resistance of the elements. 

You should get the following readings. 
Loading (kW)    Resistance (Ohms) 
9.5

 

                 12.0                                 

10.8                     10.6                                     
12.0                      9.6 

 

The heater should only draw the 
following currents: 
40 amps for the 9.5kW model                          

45 amps for the 10.8kW model             
50 amps for the 12.0kW model 

Water flow too low or 
temperature too high 

The service valve is fitted to the 
OUTLET. 

 

There are constrictions in the 
plumbing. 

Fit the service valve to the INLET of 
the unit 

 

Check the plumbing. Only use PTFE 
tape for making pipe joints 

Water goes from hot to 

cold 

The service valve is fitted to the 

OUTLET. 

Fit the service valve to the INLET of 

the unit 

 
 

 

Summary of Contents for Multiflow 10.8kW

Page 1: ...h the user after installation and demonstration It should be kept in a safe place as you may need to refer to it for general instructions or future maintenance HEATSTORE MULTIFLOW UNVENTED INSTANTANEOUS WATER HEATER Installation and User Guide ...

Page 2: ... the current edition of BS 7671 the IEE Wiring Regulations and Part P of the Building Regulations in force at the time of installation Installations outside England and Wales must also conform to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply Ensure that the mains water supply m...

Page 3: ...namic Water Pressure Basin Shower Minimum Maximum Minimum Maximum Up to 9 5kW 10 psi 0 7 bar 69 kPa 150 psi 10 3 bar 1035 kPa 15 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa Up to 10 8kW 15 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa 20 psi 1 4 bar 138 kPa 150 psi 10 3 bar 1035 kPa Up to 12 0kW 20 psi 1 4 bar 138 kPa 150 psi 10 3 bar 1035 kPa 25 psi 1 8 bar 172 kPa 150 psi 10 3 bar 1035 kPa FIX...

Page 4: ... the backplate diagram 3 Feed the cable through the grommet before you fix the unit to the wall Fixing to the wall Undo the retaining nuts and take the front cover off the unit Hold the backplate in position against the wall whilst you mark the four fixing holes Drill the holes and fix the unit to the wall using the screws supplied Plumbing the unit WARNING IF A NON RETURN VALVE IS FITTED IN THE I...

Page 5: ...Connecting the unit to the pipes The inlet and outlet are clearly marked on the unit They each have a Ø15mm straight shank connections The unit comes with a service valve diagram 5 which should be fitted on the inlet of the unit The valve can be used to turn off the water supply to the unit if it needs servicing or to reduce the main supply flow if it is too high Fitting the attachments If the uni...

Page 6: ... 6 point X to X to enable 10mm and 16mm to be correctly installed No cutting is required for 6mm cable In all cases the outer sheath of the cable MUST project through the grommet diagram 6 if side entry is used This will prevent water getting into the unit Strip back the insulation on the LIVE brown or red and NEUTRAL blue or black mains wires about 8mm Strip back any insulation on the EARTH green...

Page 7: ...on light goes out then turn it back until the neon just comes on check the water temperature at the handset and if necessary turn the cold tap on and adjust to get the desired shower temperature WARNING YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR AND DAMAGE REPLACE IF NECESSARY OR EVERY TWO YEARS WITH OUR APPROVED PART WARNING IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST DE...

Page 8: ...shed do not switch off the power if you are going to use the unit again shortly Shower Check that the power is switched on at the mains local isolator switch Turn on the hot or flow tap FULLY diagram 9 If the unit has been used recently run the water through for a few seconds to let the temperature settle down we advise you DO NOT enter the water flow during this time WARNING YOU MAY INITIALLY GET...

Page 9: ... the thermal cut out is operating A second outlet has been turned on Increase the supply water flow Make sure that the service valve is correctly adjusted Do not use the basin whilst using the shower Shower spray pattern deteriorates The shower handset is clogged Clean the handset using a descaling solution if required see page 9 We offer a technical advisory service on the telephone to installers...

Page 10: ...n supply to the INLET marked in blue Use a pump to boost the supply from a storage tank Reset it by opening the unit and pushing the button on the cut out diagram 11 Before you do this you must remove the cause of the problem Contact Heatstore Water too cold neon light on The power select screw is set to LO One element is not working The Power Supply Voltage has dropped Change the power select scr...

Page 11: ...s means that with the 12 0kW unit you can shower at 39 C with a flow rate of 5 litres minute in the middle of winter The unit includes a dual thermal cut out diagram 11 which is attached to the heat exchanger tube It will switch off the heater elements if the water flow is reduced too much and the temperature goes above a set limit The first stage cut out is cyclic and will automatically reset as ...

Page 12: ... NOT cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance including the build up of limescale The unit MUST NOT be fitted to any type of thermostatic mixer valve or tap The unit MUST NOT be fitted to a bath or kitchen sink other than for hand washing purposes It is the responsibility of the installer to check that the installation parameters meet ...

Reviews: