1.1 Introduction 

This instruction manual descr

ibes the Heatstore 

Surface Warm Air Ceiling Heaters.  

The heater is designed to be suspended from the 
ceiling. 

1.2 General

 

All installations must be in accordance with the 
regulations in force in the country of use. 

These instructions must be handed to the user on 
completion of the installation. 

Installers and service engineers must be able to 
demonstrate competence and be suitably    
qualified in accordance with the regulations in 
force in the country of use. 

To ensure continued and safe operation it is     
recommended that the appliance is serviced 
annually. 
The heater outlet / inlet must not be obstructed 
during use. 

1.3

 

Electrical Supply

Electrical supply is 230/240V single phase,     
Neutral and Earth. The maximum cable inlet size is 
4mm².  
It is recommended that the electrical supply to the 
base unit in the heater is via an appropriate 
switched isolator in accordance with the    
regulations in force in the country of use and must 
be via a fused isolator having a contact separation 
of greater than 3mm on all poles. 
BMS control, time switches, room thermostats and 
door interlocks can be installed at the discretion 
and responsibility of the installer. 

All units must be wired in accordance with I.E.E 
regulations for the Electrical Equipment of    
Buildings and the installer should ensure that a   
suitable isolating switch is connected in the mains 
supply. 

1.4 Controller 

RF

 models

The HSSCH3000RF and HSSCH4500RF will only 
operate when paired and controlled by the RF 
range of wireless controllers shown above.

1.6 Location 

All units should be installed horizontally. It is 
recommended that the ceiling  heater is    
suspended using four 10mm rods. 

Care must be taken to allow complete free air 
movement into the inlet grilles of the unit to     
ensure the correct working operation of the   
heater. If the HSSCH3000RF and the HSSCH4500RF
heaters are mounted close to the wall or corner 
the     discharge opening should be facing the 
wall. The minimum distance from the wall

.

1.7 Clearance distances 

It is acceptable for the heater to sit flush to the 
ceiling. 

The minimum mounting height (floor to grille) is 
2.2m for the HSSCH3000RF and the HSSCH4500RF

The recommended mounting height is 2.5m for 
the HSSCH3000RF and the HSSCH4500RF

Heatstore RF Wireless Controllers

HSPBRF

HSTIRF

HSVTRF

1

 

.

 

General Information

Summary of Contents for HSPBRF

Page 1: ...information 1 Dimensions 2 Installation Details 3 Electrical Connections 4 Operation 5 Servicing Maintenance 6 SURFACE WARM CEILING HEATERS MODELS HSSCH3000RF HSSCH4500RF INSTALLATION AND OPERATING MANUAL HSPBRF HSTIRF HSVTRF ...

Page 2: ...ntrol time switches room thermostats and door interlocks can be installed at the discretion and responsibility of the installer All units must be wired in accordance with I E E regulations for the Electrical Equipment of Buildings and the installer should ensure that a suitable isolating switch is connected in the mains supply 1 4 Controller RF models The HSSCH3000RF and HSSCH4500RF will only oper...

Page 3: ...Sole liability rests with the installer to ensure that protective safety wear such as hand eye ear and head protection is used during installation of the product Do not rest anything especially ladders against the product 1 10 Standards Units conform to the European electrical standard BS EN 60335 2 30 HSSCH3000RF HSSCH4500RF HSSCH3000RF HSSCH4500RF 1 General Information 2 Dimensions ...

Page 4: ...low It is required that two 10 mm hanging rods stud bars support each appliance beam The rods pass through and into each appliance beam Support washers together with nuts locate and lock the appliance beams after adjustment to level the appliance Replace Shroud Halves The reverse of above Slide shrouds beneath and around base panel Se cure each shroud half to each appliance beam with machine screw...

Page 5: ...ller can control any number of heaters providing they are in he RF range For more details please follow the instructions supplied with the controller 4 2 Electrical connections Fig 8 Heater with terminal cover open Fig 9 Terminal cover detail Heatstore RF Wireless Controllers HSPBRF HSTIRF HSVTRF 4 Electrical Connections 5 Operation ...

Page 6: ...n of the free airflow by thermal cut outs If this happens the thermal cut outs switch off the appliance The ap pliance will not operate until the heater is discon nected from the mains supply and it has cooled down If this fault re occurs again refer to the section 6 4 fault finding 6 1 Maintenance 6 4 Fault Finding If the heater will not operate disconnect it from the mains and arrange for a cert...

Page 7: ...7 RF RF ...