MULTIPOINT 30/50
5
4.0 INSTALLATION - PLUMBING
4.1
Refer to the section IMPORTANT INSTALLATION POINTS. Plumb in the valves
in the sequence shown in Diagram 1. Ensure the valves are installed in the correct
orientation by reference to the direction of flow arrows marked on them. The
Expansion Vessel should be supported by its own wall bracket (supplied),
do not
rely on the pipework alone to support it.
4.2
The water connections to the unit are 15mm diameter copper tubes suitable for
compression fittings. Do not use solder joints as this will damage the heater and
may prevent servicing under warranty.
4.3
The INLET is marked BLUE, the OUTLET is marked RED. Several hot outlets via
conventional taps can be served, however, individual site demands should be
considered when choosing capacity and the number of outlets to be served.
4.4
It is recommended that a WRAS Listed isolating valve is fitted on the cold water
supply to the heater.
4.5
A drain cock must be fitted below the heater in the inlet pipework. It must be sited
between the heater and the Check Valve (see Diagram 1). 11).
4.6
Plumbers Paste must not be used as it can impair the operation of the valves.
Diagram 3
Bracket and Levelling Feet Positions