HeatStar HSVFBF10LPTS Operating Instructions And Owner'S Manual Download Page 1

1

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

HEATSTAR, 4560 W. 160

TH

 ST., CLEVELAND, OHIO 44135 · 800-251-0001

2016 - CB

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. 

UNVENTED LP-GAS FIRED ROOM HEATER

HSVFBF10LPTS

HSVFRD10LPTS

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions in a safe 

place for future reference. Do not allow anyone who has not read these instructions to assemble, 
light, adjust or operate the heater.

Model #

 

WARNING:

 If the information in this manual is not followed exactly, a fi re or explosion may result causing 

 

property damage, personal injury, or loss of life. 

- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

 

• Shut off gas supply

 

• Do not try to light any appliance

 

• Do not touch an electrical switch; do not use any phone in your building.

 

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

 

• If you cannot reach your gas supplier, call the fi re department.

- Installation and service must be performed by a qualifi ed installer, service agency, or the gas supplier.

WARNING

: This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. 

Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion and 
Ventilation section on page 4 of this manual. 

WARNING

: Improper installation, adjustment, alteration, service or maintenance can cause injury or property 

damage. Refer to this manual for correct installation and operational procedures. For assistance or additional 
information consult a qualifi ed installer, service agency, or gas supplier. 

This appliance may be installed in an aftermarket permanently manufactured (mobile) home, where not prohibited 
by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not 
convertible for use with any other gas. 

Blue Flame Heaters

HSVFBF10LPTS

Plaque Heaters 

HSVFRD10LPTS

Summary of Contents for HSVFBF10LPTS

Page 1: ...not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installe...

Page 2: ...nversion is not permitted WARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous Do not place clothing or other flammable ma terial on or near the appliance Due to high temperatures heater should be kept out of traffic and away from furniture and draperies Surface of heater becomes very hot when running Keep childre...

Page 3: ...ir If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a wh...

Page 4: ...smaller than defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by the methods described in the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 or applicable local codes SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensor ODS safety shut off system The ODS pilot shuts off the heater if there ...

Page 5: ... space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet and the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or a...

Page 6: ...t 18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall covering or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc are present in the air may discolor walls WARNING...

Page 7: ...is firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry Note Wall anchors mounting screws and spacer are in hardware package The hardware package is provided with heater 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least 1 deep 2 ...

Page 8: ...off valve union and plugged 1 8 NPT tap Locate NPT tap within reach of test gauge hookup NPT tap must be upstream from heater see figure 11 A CSA AGA certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA AGA certified equipment shutoff valve from your dealer IMPORTANT Install an equipment shutoff valve in an accessible location Th...

Page 9: ...r front panel OPERATING YOUR HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot that must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sur...

Page 10: ...back and forth while depressed until pilot lights 7 Keep control knob depressed in for ten 10 seconds after lighting pilot If pilot goes out repeat steps 4 5 6 and 7 If pilot does not stay lit refer to Troubleshoot ing pages 12 13 Also contact a qualified service person or gas supplier for repairs If control knob does not pop up when released contact a qualified service person or gas supplier for ...

Page 11: ...tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the blow position using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assembly In addition the directions that follow shou...

Page 12: ...6 Replace thermocouple 7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Clean burner orifice see Cleaning and Maintenance on page 11 or replace burner orifice 2 Replace burner orifice 3 Contact local gas company Delayed ignition of burner 1 Manifold pressure is too low 2 Burner orif...

Page 13: ...ing Gas Connections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections page 9 Heater produces a clicking ticking noise just after burner is lit or shut off 1 Metal expanding while heati...

Page 14: ...sembly w Thermocouple LP 1 20 70640 Thermostat Valve 1 8 80017 Burner Assembly 1 21 80019 Ignitor Pulse 1 9 80009 Orifice 1 22 80014 Ignitor Wire 1 10 80069 Burner Right Bracket 1 23 8001 1 Ignitor Bracket 1 11 80016 Elbow Adapter 90 Regulator Connection 1 24 80010 Thermostat Valve Mounting Bracket 1 12 80078 Regulator 1 25 80034 Glass Bracket 1 13 80055 Regulator Mounting Bracket 1 26 70569 Hose ...

Page 15: ...PART DESCRIPTION QTY 1 80040 Wire Guard 1 1 1 80020 Regulator Connection 1 2 80051 Front Panel 1 12 80058 Floor Mounting Feet 1 3 80024 Reflector 1 13 80052 Back Panel 1 4 80030 Burner Assembly 1 14 80036 Wall Mounting Bracket 1 5 80056 ODS Pilot Assembly w Thermocouple LP 1 15 80028 Heat Shield 1 6 80032 ODS Bottom Bracket 1 16 80053 Back Heat Shield 1 7 80050 Fireproof Plate 1 17 70640 Thermosta...

Page 16: ...rom defects in material and workmanship for a period of 5 year from date of purchase Enerco Technical Products Inc will repair or replace this product free of charge if it has been proven to be defective within the 5 year period and is returned at customer expense with proof of purchase to Enerco Technical Products Inc within the warranty period This warranty gives you specific legal rights and yo...