![HeatStar HS115IR Operating Instructions And Owner'S Manual Download Page 3](http://html1.mh-extra.com/html/heatstar/hs115ir/hs115ir_operating-instructions-and-owners-manual_2117820003.webp)
3
Fuel Fired Portable Radiant Construction Heater
Operating Instructions and Owner’s Manual
IMPORTANT:
Before using the heater, read and understand all instruc
-
tions and follow them carefully. The manufacturer
is not responsible for damages to goods or persons due to
improper use of units.
GENERAL RECOMMENDATIONS
The heater described in this manual is a portable oil-fueled
infrared heater running on heating oil. Its easy handling
and large fuel tank allow it to be used locally and tempo-
rarily with complete stand-alone operation. The area to
be heated is therefore hit by an even and uniform flow of
heat, without air movement. The unit is a direct combus-
tion heater that works by sending both hot air and combus-
tion products in the room you wish to heat: all the neces-
sary precautions must therefore be taken to guarantee a
sufficient exchange of air.
Always follow local ordinances and codes when using
this heater:
• Read and follow this owner’s manual before using the
heater;
• THE INSTALLATION OF THE UNIT SHALL BE IN ACCOR
-
DANCE WITH THE REGULATIONS OF THE AUTHORI
-
TIES HAVING JURISDICTION IN YOUR AREA. Also, as
a recommended operation practice reference should
be made to the current issue of CSA B139, Installation
Code for Oil Burning Equipment in Canada and NFPA
31 Standard for the Installation of Oil-Burning Equip
-
ment In the USA;
• Use only in places free of flammable vapors or high
dust content;
• Never use heater in immediate proximity of flammable
materials (the minimum distance must be 10 feet);
•
Make sure fire fighting equipment is readily available;
•
Make sure sufficient fresh outside air is provided ac-
THERMOELECTRIC SPECIFICATIONS
Consumption @ 0°C
Lb/HR
2.67
Kg/HR
5.88
US GAL/HR
0.849
EFFICIENCY
%
100
UPPER CALORIFIC VALUE
HEAT INPUT
BTU/HR
115,160
Kw
33.5
kcal/h
28,790
HEAT output
BTU/HR
115,160
Kw
33.5
kcal/h
28,790
LOWER CALORIFIC VALUE
HEAT INPUT
BTU/HR
109,402
Kw
31.8
kcal/h
27,351
HEAT output
BTU/HR
109,402
Kw
31.8
kcal/h
27,351
PUMP PRESSURE
(Factory set)
174PSI
12 bar
SMOKE BACHARACH INDEX
0
COMBUSTION AIR SETTING
POSITION HEAD
IN
0.126
MM
3.2
NOISE LEVEL @ 3’
AVERAGE Dba
69.5
RUN TIME
TANK CAP
11.3GAL
RUNTIME(HOURS)
13.4
OIL NOZZLE
TYPE
DELAVAN
80°W
FLOW
GPH
0.6
OIL PUMP
TYPE
SUNTEC
CS 30
MOTOR
POWER
200W
CURRENT
3.8A
RPM
3300
OVERHEAT THERMOSTAT
SET POINT
170° C
ELECTRONIC FLAME CONTROL
MANUFACTURER
BRAHMA
TYPE
TGRD 71
APPROVAL
UL
CENTRIFIGUAL FAN
DIAMETER
133MM
METAL THICKNESS
50MM
SUCTION AIR DISK I.D.
76MM
WHEELS
DIAMETER
9.843"
SHAFT DIAMETER
.98"
POWER SUPPLY
INPUT
120V
60Hz
POWER AND CURRENT
210W
2.15 A
FUSE 3.15A "T" STYLE
HS115IR WEIGHTS AND DIMENSIONS
DRY
WEIGHT
92.5LB
FULL
WEIGHT
173.02LB
LENGTH
35.25"
HEIGHT
31.81"
WIDTH
20.94
SHIPPING DIMENSIONS
LENGTH
29.1"
HEIGHT
27.76"
WIDTH
22.4"
WEIGHT
104LBS
SPECIFICATIONS