Heatscope MHS-NM2400 Original Installation And Instruction Manual Download Page 8

11.   The power cable or buried cable with omnipolar switch may only be replaced by a profes

-

sional specialist electrical company enlisted or approved by the manufacturer. Heating 

elements, other components or parts of the housing may only be replaced by a service 

organisation enlisted by the manufacturer. If you yourself or someone enlisted by you car-

ries out repairs, they will not be covered by the guarantee. Improper repairs and incorrect 

installation or operation shall invalidate the guarantee immediately.

12.   If the heater was installed inappropriately or was connected unhomogeneously with the 

local electrical supply cable, high transfer resistances may occur, which lead to overhe

-

ating of the device. If overheating of a carbon heating element occur due to interlinkage 

of mounting and installation mistakes, the carbon filaments inside of the quarz tubes will 

fuse and safely disconnect the current flow.

 

Even after a mechanical break of the quarz 

tubes, the carbon heating spirals will not work any longer. Besides the glass ceramic, 

high temperature resistant front screen of the heaters provide best protection of the 

installed carbon heating elements.  If a system malfunction inside the device causes 

the shut down, the heater must be repaired by a professional technician; please contact 

your dealer immediately. If a wrong cable connection causes the shut down, this has to 

be checked and fixed through a professional electrician on the spot. Installation and con

-

necting regulations with tested and approved luster terminals are part of the delivered 

equipment.

13.  The radiant heater must not be installed directly below a power source/socket. The sides 

of the unit must be at least 20 cm from the nearest power source. Sockets/power sour

-

ces must be freely accessible at all times and comply with the following specifications: 

220–240 V AC ~, 50/60 Hz, 16 A with 16 A fuse. No other loads may be connected to 

this power source.

14.   The radiant heater must not be installed in or in close vicinity to bathtubes, showers or 

pools, nor in rooms where there is permanent high humidity (DIN VDE 0100-701). The di

-

stance to the bathtub or shower must be at least 100 cm and the distance to the pool at 

least 200 cm. A person standing in the bathtube, shower or pool should never reach the 

switch or controller of the heater. If the HEATSCOPE

®

 is installed in such an environment 

with high humidity, the switches or other operating components must be positioned in 

such a way that they cannot be touched by persons who are in direct contact with water. 

When a radiant heater is installed in a bathroom, the CE standard requires that at least 

one heating element visibly „glows“ as soon as the unit is switched on.

15.   The heater must not be installed nor operated in environments containing chlorine (like 

inside pool areas) or salt (like near the coast). 

16.   Disconnect the radiant heater from the power supply before cleaning it, adjusting the 

angle or removing it from the wall/ceiling. Wait until the heating elements are not glowing 

any more and the housing is noticably cooled down.  If buried cables are used, switch off 

the power using an omnipolar switch. Wait at least 30 minutes after the last use before 

EN

Summary of Contents for MHS-NM2400

Page 1: ...UCHSANLEITUNG Elektrischer Design Carbon Heizstrahler f r Innen und Au enbereiche ORIGINAL INSTALLATION AND INSTRUCTION MANUAL Electric design carbon radiant heater for indoor and outdoor areas EN DE...

Page 2: ...en und die daraus resultierenden Gefahren verstanden haben vorausgesetzt das Ger t ist in seiner normalen Gebrauchslage installiert Dieses Ger t kann von Kindern ab 8 Jahren und lter sowie von Persone...

Page 3: ...HEATSCOPE w hrend des Betriebs bzw bis 30 Minuten nach Ausschalten 6 Das Trocknen von Textilien oder anderen Materialien mit Hilfe des HEATSCOPE ist grund s tzlich verboten Bei Abdeckung des Heizstra...

Page 4: ...n bergangswiderst nde entstehen die zur berhitzung des Systems f hren Bei Fehlern innerhalb des Systems oder Fehlern in der elektrischen Installation muss der Heizstrahler vor erneutem Einschalten dur...

Page 5: ...Pflege ist der HEATSCOPE stets von der Stromquelle zu trennen bzw bei Festeinbau allpolig abzuschalten Vergewissern Sie sich dass das Ger t abgek hlt ist warten Sie nach dem letzten Gebrauch mindeste...

Page 6: ...physical sensory or mental abilities or lack of experience and or knowledge can use this unit if they are overseen or if they were instructed how to use the unit safely and have received instructions...

Page 7: ...into contact with the surface of the radiant heater and never cover the unit Under no cir cumstances should the unit be covered or enclosed with insulating or similar materials Adequate ventilation s...

Page 8: ...tested and approved luster terminals are part of the delivered equipment 13 The radiant heater must not be installed directly below a power source socket The sides of the unit must be at least 20 cm...

Page 9: ...ed using a damp cloth only Never use cleaning products containing alkaline substances such as sodium hydroxide or soap sur factants or solvents such as alcohol Use only a very soft cloth or a brush fo...

Page 10: ...za zen jsou b hem pou v n velmi hork a mohou zp sobit pop le niny Vysok opatrnost je nezbytn nutn pokud jsou v m stnosti d ti nebo osoby s omezen mi fyzick mi smyslov mi nebo ment ln mi schopnostmi i...

Page 11: ...axim ln 15 20 vte in ne se za zen zah eje na provozn teplo tu 5 VAROV N Hroz riziko pop len eln sklo cca 300 C a p edn ochrann m ka cca 400 C dosahuj b hem pou v n velmi vysok ch teplot Nezakr vejte n...

Page 12: ...van m karbonov m topn m t les m Pokud z vada syst mu uvnit za zen zp sob vypnut p stroje mus b t topidlo opraveno odborn m technikem okam it kontaktujte prodejce Pokud vyp nut zp sob nespr vn zapojen...

Page 13: ...dne Pokud pou v te zemn kabel vypn te p vod elekt iny omni pol rn m sp na em Vy kejte alespo 30 minut ne za nete s i t n m V echny povrchy by m ly b t i t ny pouze vlhk m had kem Nikdy nepou vejte pro...

Page 14: ...L L PE N L 220 240 V AC 50 60 Hz PE N II 50 I 50 Trennschalter Sicherungsschalter installationsseitig Circuit breaker fuse switch on the installation side Jisti pojistkov sp na na stran instalace MANU...

Page 15: ...A M B I E N T H E A T I N G S O L U T I O N S VERSION 02 MONTAGE MOUNTING MONT VERSION 01...

Page 16: ...2 1 MONTAGE MOUNTING MONT 1X 1X...

Page 17: ...A M B I E N T H E A T I N G S O L U T I O N S 3 4 5 6...

Page 18: ...180cm 25 cm 40cm 40cm 180cm 25 cm 180cm 150cm 150cm 180cm 15 cm 40cm X MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 40cm...

Page 19: ...A M B I E N T H E A T I N G S O L U T I O N S 15cm 180cm X X 40cm 40cm 200cm 40cm 200cm 40cm...

Page 20: ...200cm 15cm X MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 10cm X 150cm...

Page 21: ...A M B I E N T H E A T I N G S O L U T I O N S 180cm 25 cm 150cm X X 180cm 25 cm 150cm X X MINDESTABST NDE GLAS MINIMUM DISTANCES GLASS MINIM LN ODSTUPY OD SKLA...

Page 22: ...MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 40cm 40cm 180cm 40cm 40cm...

Page 23: ...A M B I E N T H E A T I N G S O L U T I O N S 200cm 40cm 40cm 40cm...

Page 24: ...penschild des HEATSCOPE angegeben ist Diese Bedienungsanleitung ist ausschlie lich f r die erh ltlichen Serienprodukte bestimmt Bei Sonderanfer tigungen k nnen Abweichungen der technischen Daten der M...

Page 25: ...an kann den Heizstrahler direkt am Ger t mit zwei Drucktastern manuell steuern Der Anschluss an einen Fehlerstromschutzschal ter und eine Sicherung ist obligatorisch ACHTUNG Die Montage der Heizstrahl...

Page 26: ...em Tag an dem das Neuger t erworben wurde Verschlei teile oder M ngel die die Gebrauchstauglichkeit des Ger tes nur unerheblich beeinflussen sind von der Garantie ausgeschlossen Der Garantieanspruch m...

Page 27: ...er nicht autorisierte Stelle ge ffnet ver ndert modifiziert umgebaut oder repariert wurde Die Konformit tserkl rung CE WEEE RoHS erhalten Sie auf Wunsch direkt beim Hersteller Es sind keine Ma nahmen...

Page 28: ...zustand elSB in kW N A Obligatorische Produktinformationen gem EU 2015 1188 kodesign Richtlinie Der HEATSCOPE Heizstrahler PE NM Reihe wird direkt durch den kodesign zertifizierten Raum thermostat DEV...

Page 29: ...M GLICH Raumtemperaturkontrolle mit Pr senzerkennung Nein Raumtemperaturkontrolle mit Erkennung offener Fenster Ja mit Fernbedienungsoption Ja mit adaptiver Regelung des Heizbeginns Nein mit Betriebsz...

Page 30: ...he rating plate of the HEATSCOPE unit This instruction manual is intended solely for the standard products available The technical data ins tallation requirements and dimensions of custom made special...

Page 31: ...d the unit you can use it for the first time The HEATSCOPE features two omnipolar ON OFF switches You can control the radiant heater manu ally using these selector switches on the unit itself The unit...

Page 32: ...egins with the date on which the new unit was purchased Expendable parts or defects that affect the usability of the unit only slightly are not covered by the guarantee When making a guarantee claim y...

Page 33: ...epaired by a per son not authorized by the manufacturer The declaration of conformity CE WEEE RoHS is available upon request from the manufacturer EN No action is needed to switch the device between 5...

Page 34: ...ogrammed ambient temperature in the weekday routine at any set point of time ready 2015 1188 FULFILLS THE STANDARDS OF THE EU ECODESIGN DIRECTIVE 2009 125 EG ErP ready 2015 1188 EN Modell MHS PE2400 M...

Page 35: ...ature control and attendance detection No room temperature control with open window detection Yes incl remote control option Yes incl adaptive regulation of heating inception No incl operating time li...

Page 36: ...n kem nebo odbornou firmou Tento manu l je zam len k pou it v hradn se standardn vyr b n m produktem Technick data po adavky na instalaci a rozm ry speci ln ch na m ru vyr b n ch verz se mohou li it B...

Page 37: ...topidla na ze nebo strop stejn jako na sklo v prosklen ch domech i sklen c ch mus b t provedeno odborn podle p edpis Uveden minim ln odstupy jsou ch p ny jako minim ln hodnoty a mohou se li it od m s...

Page 38: ...zen pouze v p pad e bude vr ceno adekv tn zabalen a p ipraven k p evozu aby byl zaji t n bezpe n transport V robce dle vlastn ho uv en spln sv z ru n povinnosti bu opravou nebo v m nou vadn ho za zen...

Page 39: ...p i 240 V AC 2500 W 3200 W Elektrick proud 10 43 A 13 33 A Nap jec kabel 1 1 m 4 x 1 5 mm2 Max teplota topn plochy vp edu 400 C 300 C Max teplota pl t 120 C 120 C Teplota topn ch vl ken 1100 1300 C N...

Page 40: ...pokojov teploty v b n m v ednodenn m m du k dan mu okam iku ready 2015 1188 FULFILLS THE STANDARDS OF THE EU ECODESIGN DIRECTIVE 2009 125 EG ErP ready 2015 1188 CZ Model MHS PE2400 MHS PE3000 TEPELN V...

Page 41: ...o DAL MON NOSTI OVL D N ovl d n pokojov teploty a detekce p tomnosti osob Ne ovl d n pokojov teploty a detekce otev en ch oken Ano v mo nosti d lkov ho ovl d n Ano v adapitivn regulace zah v n Ne v om...

Page 42: ...ux Belgium The Netherlands Luxembourg MOONICH GmbH Kramergasse 32 D 82054 Sauerlach Lochhofen Tel 49 8104 647090 Fax 49 8104 647099 heatscope moonich de www moonich de THE NORTHERN COUNTRIES Denmark S...

Reviews: