![Heatscope MHS-NM2400 Original Installation And Instruction Manual Download Page 33](http://html1.mh-extra.com/html/heatscope/mhs-nm2400/mhs-nm2400_original-installation-and-instruction-manual_2117754033.webp)
A M B I E N T H E A T I N G S O L U T I O N S
WARRANTY EXCLUSIONS
Damage or defects caused by improper handling or operation as well as defects caused by using non-
original parts or the use of accessories not recommended by the manufacturer are not covered by the
warranty.
The warranty does not cover damages caused by external influences such as fire, lightning or any trans
-
port damages. Liability for consequential damages to persons or property is excluded.
If the serial number of the unit has been changed, removed or defaced, the warranty will be invalid.
All warranty claims shall be forfeited if the unit is opened, altered, modified, rebuilt or repaired by a per
-
son not authorized by the manufacturer.
The declaration of conformity (CE, WEEE, RoHS) is available upon request from the manufacturer.
EN
No action is needed to switch the device between 50Hz and 60Hz.
The product will adapt itself for both 50Hz and 60Hz.
TECHNICAL DATA
HEATSCOPE
®
NEXT
HEATSCOPE
®
PURE
Operating voltage
220-240 V AC ~, 50/60 Hz
220-240V AC ~, 50/60 Hz
Power at 240 V AC~
2500 W / 3200 W
Current
10.43 A / 13.33 A
Power Cord
1.1 m / 4 x 1.5 mm
2
Max. surface temperature / front
≤ 400 °C
≤ 300 °C
Max. housing temperature
≤ 120 °C
≤ 120 °C
Filament temperature
1100–1300 °C
Heating impact in
15 Sek.
30 Sek.
Max. visible light
≤ 600 lumen
≤ 300–400 lumen
Installation height
min. 1.8 m / max. 3.0 m
min. 1.8 m / max. 2.7 m
IP protection class
IP 25
IP 65
Manual control
ON/OFF + 100%, 50%
Remote control (SMARTBOX)
ON/OFF + 100%, 50%
Measurements / Weight
1044 x 166 x 87 mm / 7.5 kg
Summary of Contents for MHS-NM2400
Page 15: ...A M B I E N T H E A T I N G S O L U T I O N S VERSION 02 MONTAGE MOUNTING MONT VERSION 01...
Page 16: ...2 1 MONTAGE MOUNTING MONT 1X 1X...
Page 17: ...A M B I E N T H E A T I N G S O L U T I O N S 3 4 5 6...
Page 19: ...A M B I E N T H E A T I N G S O L U T I O N S 15cm 180cm X X 40cm 40cm 200cm 40cm 200cm 40cm...
Page 20: ...200cm 15cm X MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 10cm X 150cm...
Page 22: ...MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 40cm 40cm 180cm 40cm 40cm...
Page 23: ...A M B I E N T H E A T I N G S O L U T I O N S 200cm 40cm 40cm 40cm...