SAFETY INFORMATION

HEATSCOPE

®

 infrared heaters must be installed and executed only by an authorized expert / 

professional electrician.

All relevant local building and fire safety regulations must be observed.

WARNING: This unit is not equipped with an application to regulate the room temperature.

 

The heater must not be used in small rooms inhabited by people who cannot leave the room 

unaided, unless constant supervision is ensured.

Be careful when operating the unit. Children younger than 3 years must be kept away, 

unless they are overseen all the time. Children older than 3 years and younger than 8 years 

are allowed to switch on and off the unit, if they are overseen, or if they were instructed how 

to use the unit safely and have received instructions how to operate/use the unit, assumed 

the unit is installed properly. 

CAUTION: Some parts of the unit get very hot and may cause burns! High cautiousness is 

imperative, if children or persons with reduced physical, sensory or mental abilities or lack 

of experience and/or knowledge. are present in the room.

Children older than 3 years and younger than 8 years are not allowed to connect the plug, to 

control the unit, to clean the unit and/or to maintain the unit. 

Children older than 8 years and persons with reduced physical, sensory or mental abilities 

or lack of experience and/or knowledge can use this unit, if they are overseen, or if they 

were instructed how to use the unit safely and have received instructions how to operate/

use the unit and which endangerments may result during the use of the unit. Children must 

not be playing with the unit. Cleaning and maintenance must not be done by children, un-

less they are supervised by a person responsible for their safety.

The unit must never be used unattended. Children must be supervised at all  

times to ensure that they do not play with the unit, switch it on unintentionally  

or adjust it.

1.   Please check that your HEATSCOPE

®

 radiant heater and accessories are com plete and 

not damaged.  If the housing or reflector is deformed/damaged or the heating element is 

broken, do not use the HEATSCOPE

®

 unit. Please contact the vendor or the manufacturer. 

The cable must not be crushed, squeezed or damaged. If the unit or accessories show 

signs of defects, cracking, breakage or other damage or if the industrial glass ceramics 

screen is damaged, discontinue use and have them repaired. In this case, disconnect 

the unit from the power supply, return it to the manufacturer or dispose of it. The unit 

should be labelled accordingly to prevent it being reconnected.

2.   For installation use only the supplied accessories or original accessories approved by the 

manufacturer. The power cable or other components of the HEATSCOPE

®

 radiant heater 

EN

Summary of Contents for MHS-NM2400

Page 1: ...UCHSANLEITUNG Elektrischer Design Carbon Heizstrahler f r Innen und Au enbereiche ORIGINAL INSTALLATION AND INSTRUCTION MANUAL Electric design carbon radiant heater for indoor and outdoor areas EN DE...

Page 2: ...en und die daraus resultierenden Gefahren verstanden haben vorausgesetzt das Ger t ist in seiner normalen Gebrauchslage installiert Dieses Ger t kann von Kindern ab 8 Jahren und lter sowie von Persone...

Page 3: ...HEATSCOPE w hrend des Betriebs bzw bis 30 Minuten nach Ausschalten 6 Das Trocknen von Textilien oder anderen Materialien mit Hilfe des HEATSCOPE ist grund s tzlich verboten Bei Abdeckung des Heizstra...

Page 4: ...n bergangswiderst nde entstehen die zur berhitzung des Systems f hren Bei Fehlern innerhalb des Systems oder Fehlern in der elektrischen Installation muss der Heizstrahler vor erneutem Einschalten dur...

Page 5: ...Pflege ist der HEATSCOPE stets von der Stromquelle zu trennen bzw bei Festeinbau allpolig abzuschalten Vergewissern Sie sich dass das Ger t abgek hlt ist warten Sie nach dem letzten Gebrauch mindeste...

Page 6: ...physical sensory or mental abilities or lack of experience and or knowledge can use this unit if they are overseen or if they were instructed how to use the unit safely and have received instructions...

Page 7: ...into contact with the surface of the radiant heater and never cover the unit Under no cir cumstances should the unit be covered or enclosed with insulating or similar materials Adequate ventilation s...

Page 8: ...tested and approved luster terminals are part of the delivered equipment 13 The radiant heater must not be installed directly below a power source socket The sides of the unit must be at least 20 cm...

Page 9: ...ed using a damp cloth only Never use cleaning products containing alkaline substances such as sodium hydroxide or soap sur factants or solvents such as alcohol Use only a very soft cloth or a brush fo...

Page 10: ...za zen jsou b hem pou v n velmi hork a mohou zp sobit pop le niny Vysok opatrnost je nezbytn nutn pokud jsou v m stnosti d ti nebo osoby s omezen mi fyzick mi smyslov mi nebo ment ln mi schopnostmi i...

Page 11: ...axim ln 15 20 vte in ne se za zen zah eje na provozn teplo tu 5 VAROV N Hroz riziko pop len eln sklo cca 300 C a p edn ochrann m ka cca 400 C dosahuj b hem pou v n velmi vysok ch teplot Nezakr vejte n...

Page 12: ...van m karbonov m topn m t les m Pokud z vada syst mu uvnit za zen zp sob vypnut p stroje mus b t topidlo opraveno odborn m technikem okam it kontaktujte prodejce Pokud vyp nut zp sob nespr vn zapojen...

Page 13: ...dne Pokud pou v te zemn kabel vypn te p vod elekt iny omni pol rn m sp na em Vy kejte alespo 30 minut ne za nete s i t n m V echny povrchy by m ly b t i t ny pouze vlhk m had kem Nikdy nepou vejte pro...

Page 14: ...L L PE N L 220 240 V AC 50 60 Hz PE N II 50 I 50 Trennschalter Sicherungsschalter installationsseitig Circuit breaker fuse switch on the installation side Jisti pojistkov sp na na stran instalace MANU...

Page 15: ...A M B I E N T H E A T I N G S O L U T I O N S VERSION 02 MONTAGE MOUNTING MONT VERSION 01...

Page 16: ...2 1 MONTAGE MOUNTING MONT 1X 1X...

Page 17: ...A M B I E N T H E A T I N G S O L U T I O N S 3 4 5 6...

Page 18: ...180cm 25 cm 40cm 40cm 180cm 25 cm 180cm 150cm 150cm 180cm 15 cm 40cm X MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 40cm...

Page 19: ...A M B I E N T H E A T I N G S O L U T I O N S 15cm 180cm X X 40cm 40cm 200cm 40cm 200cm 40cm...

Page 20: ...200cm 15cm X MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 10cm X 150cm...

Page 21: ...A M B I E N T H E A T I N G S O L U T I O N S 180cm 25 cm 150cm X X 180cm 25 cm 150cm X X MINDESTABST NDE GLAS MINIMUM DISTANCES GLASS MINIM LN ODSTUPY OD SKLA...

Page 22: ...MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 40cm 40cm 180cm 40cm 40cm...

Page 23: ...A M B I E N T H E A T I N G S O L U T I O N S 200cm 40cm 40cm 40cm...

Page 24: ...penschild des HEATSCOPE angegeben ist Diese Bedienungsanleitung ist ausschlie lich f r die erh ltlichen Serienprodukte bestimmt Bei Sonderanfer tigungen k nnen Abweichungen der technischen Daten der M...

Page 25: ...an kann den Heizstrahler direkt am Ger t mit zwei Drucktastern manuell steuern Der Anschluss an einen Fehlerstromschutzschal ter und eine Sicherung ist obligatorisch ACHTUNG Die Montage der Heizstrahl...

Page 26: ...em Tag an dem das Neuger t erworben wurde Verschlei teile oder M ngel die die Gebrauchstauglichkeit des Ger tes nur unerheblich beeinflussen sind von der Garantie ausgeschlossen Der Garantieanspruch m...

Page 27: ...er nicht autorisierte Stelle ge ffnet ver ndert modifiziert umgebaut oder repariert wurde Die Konformit tserkl rung CE WEEE RoHS erhalten Sie auf Wunsch direkt beim Hersteller Es sind keine Ma nahmen...

Page 28: ...zustand elSB in kW N A Obligatorische Produktinformationen gem EU 2015 1188 kodesign Richtlinie Der HEATSCOPE Heizstrahler PE NM Reihe wird direkt durch den kodesign zertifizierten Raum thermostat DEV...

Page 29: ...M GLICH Raumtemperaturkontrolle mit Pr senzerkennung Nein Raumtemperaturkontrolle mit Erkennung offener Fenster Ja mit Fernbedienungsoption Ja mit adaptiver Regelung des Heizbeginns Nein mit Betriebsz...

Page 30: ...he rating plate of the HEATSCOPE unit This instruction manual is intended solely for the standard products available The technical data ins tallation requirements and dimensions of custom made special...

Page 31: ...d the unit you can use it for the first time The HEATSCOPE features two omnipolar ON OFF switches You can control the radiant heater manu ally using these selector switches on the unit itself The unit...

Page 32: ...egins with the date on which the new unit was purchased Expendable parts or defects that affect the usability of the unit only slightly are not covered by the guarantee When making a guarantee claim y...

Page 33: ...epaired by a per son not authorized by the manufacturer The declaration of conformity CE WEEE RoHS is available upon request from the manufacturer EN No action is needed to switch the device between 5...

Page 34: ...ogrammed ambient temperature in the weekday routine at any set point of time ready 2015 1188 FULFILLS THE STANDARDS OF THE EU ECODESIGN DIRECTIVE 2009 125 EG ErP ready 2015 1188 EN Modell MHS PE2400 M...

Page 35: ...ature control and attendance detection No room temperature control with open window detection Yes incl remote control option Yes incl adaptive regulation of heating inception No incl operating time li...

Page 36: ...n kem nebo odbornou firmou Tento manu l je zam len k pou it v hradn se standardn vyr b n m produktem Technick data po adavky na instalaci a rozm ry speci ln ch na m ru vyr b n ch verz se mohou li it B...

Page 37: ...topidla na ze nebo strop stejn jako na sklo v prosklen ch domech i sklen c ch mus b t provedeno odborn podle p edpis Uveden minim ln odstupy jsou ch p ny jako minim ln hodnoty a mohou se li it od m s...

Page 38: ...zen pouze v p pad e bude vr ceno adekv tn zabalen a p ipraven k p evozu aby byl zaji t n bezpe n transport V robce dle vlastn ho uv en spln sv z ru n povinnosti bu opravou nebo v m nou vadn ho za zen...

Page 39: ...p i 240 V AC 2500 W 3200 W Elektrick proud 10 43 A 13 33 A Nap jec kabel 1 1 m 4 x 1 5 mm2 Max teplota topn plochy vp edu 400 C 300 C Max teplota pl t 120 C 120 C Teplota topn ch vl ken 1100 1300 C N...

Page 40: ...pokojov teploty v b n m v ednodenn m m du k dan mu okam iku ready 2015 1188 FULFILLS THE STANDARDS OF THE EU ECODESIGN DIRECTIVE 2009 125 EG ErP ready 2015 1188 CZ Model MHS PE2400 MHS PE3000 TEPELN V...

Page 41: ...o DAL MON NOSTI OVL D N ovl d n pokojov teploty a detekce p tomnosti osob Ne ovl d n pokojov teploty a detekce otev en ch oken Ano v mo nosti d lkov ho ovl d n Ano v adapitivn regulace zah v n Ne v om...

Page 42: ...ux Belgium The Netherlands Luxembourg MOONICH GmbH Kramergasse 32 D 82054 Sauerlach Lochhofen Tel 49 8104 647090 Fax 49 8104 647099 heatscope moonich de www moonich de THE NORTHERN COUNTRIES Denmark S...