Heatrae Sadia SUPREME 220SS Fitting Instructions And User Manual Download Page 6

11

10

7.0 COMMISSIONING

7.1 The electronic control system of the Supreme has a self 

commissioning and calibration function.  Once the heater is 

installed and all services have been connected, the unit should 

require no further adjustment before use.

7.2 Check that all electrical, water and vent pipe connections have 

been made and are secure.

7.3 Replace the bottom cover and secure with the fixing screws.  Turn 

on water and electrical supply.

7.4 The READY indicator will flash to indicate the unit is in its “self-

commissioning” mode.  The water in the unit will not be hot 

enough to use at this stage.

7.5 The READY indicator will continue to flash until the unit has 

reached boiling and has “self-calibrated”.  At this point the READY 

indicator will remain illuminated.  If for any reason the calibration 

procedure is interrupted it will restart after a short delay but may 

result in the calibrated temperature being too low.  If this occurs 

switch the electrical supply OFF for several seconds and then 

switch ON.  The calibration sequence will reset.  Wait for the 

READY indicator to remain illuminated.

7.6 The unit is now ready to use, however, it is recommended that the 

first few fills be drawn off and discarded to ensure the freshness of 

the water.

7.7 The tap sealing washer pressure has been already set.  If the 

tap drips after commissioning adjust the spring tension so that 

the handle is just loose. With the handle in the vertical (off 

position) remove locking screw, spring washer and security tab; 

line up the hole in the plastic tap cap with the hole beneath it 

(by gently turning the handle).  Insert a short, blunt, M4 screw.  

Increase sealing pressure (and loosen handle fit) by turning the 

handle clockwise.  Remove the ‘short, blunt, M4 screw’; position 

the handle with the smoothly curved side facing you (pull on 

with spring return) and replace tab, washer and screw.   

Note: 

excessive adjustment will dismantle the tap, if heated  this 

would result in the uncontrollable release of boiling water.

7.8 Check for leaks.

8.0 MAINTENANCE

NOTE:    Maintenance must be carried out by competent persons.

Competent  -  i.e.  trained, experienced, qualified.

Disconnect  the electrical supply before removing the covers.

WARNING: electronics control by switching ‘N’ (neutral), in some 

instances neutral terminations will be at 230 volts with respect to 

earth.

8.1 The electronic control system of the Supreme has a self-diagnostic 

feature which determines if the unit is operating satisfactorily.  It 

will automatically calibrate for water quality and temperature.

8.2 If steam or boiling water discharges from the vent pipe the 

Supreme will switch off.  

 

A critical fault would render the unit 

unsafe to use and so will deactivate both the element and 

solenoid valve.

8.3 The Supreme incorporates an electronic scale conditioning 

function which will reduce the rate of scale deposition in hard 

water areas.  However, some deposits may still occur in the 

storage tank; these should be periodically removed.

Summary of Contents for SUPREME 220SS

Page 1: ...1 SUPREME 220SS 250SS 310SS 560SS Fitting Instructions and User Guide...

Page 2: ...d physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazard...

Page 3: ...not be switched on It must be left to thaw and must then be thoroughly inspected to ensure it is totally thawed and undamaged 1 9 The unit is not suitable for installation in an area where a water jet...

Page 4: ...r use with the wall If unsuitable due to wall type provide alternative fixings 3 0 INSTALLATION TAPS 3 1 Remove the tap bezel by unscrewing the 2 screws Check that tap boss thread and bore are clean R...

Page 5: ...y vent pipe is used the pipe must terminate below the unit in a safe visible position After connection DO NOT make soldered joints in the pipework close to the heater as the heat may damage the connec...

Page 6: ...handle is just loose With the handle in the vertical off position remove locking screw spring washer and security tab line up the hole in the plastic tap cap with the hole beneath it by gently turning...

Page 7: ...Y BEFORE REMOVING THE COVERS AND CARRYING OUT ANY OF THE FOLLOWING ACTIONS DO NOT BYPASS ANY SAFETY CONTROLS Any faults that cannot be identified using the Fault Finding chart or in case of doubt cont...

Page 8: ...it board 560 master control 95 615 002 13 Circuit board 560 auxiliary control 95 615 003 14 Wiring harness 4way inc diodes 95 612 006 15 Wiring harness 220 250 complete 95 612 007 Wiring harness 310 c...

Page 9: ...m of the stroke the handle will push over a gentle feature and remain open when released To move back to the off position no flow gently lift the handle To select option 1 or 2 with the handle in the...

Page 10: ...drawn off and discarded NOTES GUARANTEE This Supreme water heater is guaranteed for a period of two years from the date of purchase provided 1 The unit has been installed in accordance with these ins...

Page 11: ...574 Parts Center Network 65 Business Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co uk Newey Eyre Specialists Products Division Please contact your local branch...

Reviews: