Heatrae Sadia SUPREME 220SS Fitting Instructions And User Manual Download Page 5

9

8

4.0 INSTALLATION - WATER SUPPLY

4.1 Select appropriate push fit connector for chosen entry position: 

Bottom entry water - 15mm x 15mm 90° elbow. 

Rear entry water - 15mm x 15mm straight. 

Note: stainless or chromed pipes do NOT provide secure 

connections with push fit fittings (use copper pipe at all joints).

4.2 Push the connector fully home (28mm engagement) onto the 

solenoid valve inlet spigot.  To remove a push fit connector the 

collar(collet) should be pushed towards the body of the fitting 

whilst pulling the connector off the pipe.

4.3 Connect the inlet pipe to the push fit connector ensuring it is fully 

pushed home (28mm engagement).  After connection DO NOT 

make soldered joints in the pipework close to the heater, as the 

heat may damage the connector or the water heater itself.

4.4 To facilitate servicing a WRAS listed isolating valve must be fitted; 

the use of braided hose between the isolating valve and heater 

inlet is also suggested to improve serviceability.

4.6 Push fit connectors are supplied to allow either bottom or rear 

entry of services.  If a combination of entry points are required an 

additional connector will be required as follows: 

Bottom inlet, rear vent 15mm x 15mm elbow 

     

 

 

   (Heatrae Sadia part no. 95 607 510) 

Rear inlet, bottom vent 15mm x 15mm straight

     

 

 

   (Heatrae Sadia part no. 95 607 509)

5.0 INSTALLATION - VENT PIPE

5.1 Select appropriate push fit connector for chosen entry position: 

Bottom entry vent -15mm x 15mm straight 

Rear entry vent - 15mm x 15mm 90° elbow

5.2 Push the connector fully home (28mm engagement) onto the vent 

pipe connection.

5.3 Connect the vent pipe to the push fit connector ensuring it is 

pushed fully home (28mm engagement).  Refer to the vent 

pipe requirements detailed in 1.0 IMPORTANT INSTALLATION 

POINTS.  If a bottom entry vent pipe is used, the pipe must 

terminate below the unit in a safe visible position.  After 

connection, DO NOT make soldered joints in the pipework close 

to the heater, as the heat may damage the connector or the water 

heater itself.

6.0 INSTALLATION - ELECTRICAL 
REQUIREMENTS

WARNING: This appliance must be earthed.  It is suitable for a.c. 

supply only.  Disconnect the electrical supply before removing 

the cover.  Installation must be in accordance with the current 

local Wiring Regulations.

6.1 Supremes must only be connected via fixed wiring (a plug and 

socket must not be used). 

6.2 A double pole isolating switch, with a contact separation of at least 

3mm in both poles, should be incorporated in the electrical supply.  

The supply should be fused 13 Amp (for 3kw units) or 30 Amp for 

6kW units).

6.3 The nominal cross sectional area of the supply cable must be a 

minimum of 1.5mm

(3kW) or 4.0mm

2

 (6kW).

6.4 The outer sheath of the cable must be secured using the cable 

clamp provided, unless using conduit.  To fit 20 mm conduit 

remove the cable clamp (undo 2 screws securing the clamp to 

the bracket and pull off clamp), fit flexible conduit tail to the metal 

bracket and secure with a back nut.

6.5 Connect the cable to the terminal block as follows: 

BROWN or RED wire to terminal marked L. 

BLUE or BLACK wire to terminal marked N. 

GREEN/YELLOW or GREEN wire to terminal marked  

If using “Twin and Earth” cable the bare earth wire must be 

sleeved.   

6.6 If Supremes are to be unused for significant periods of time, 

running costs can be reduced by switching the units off.  It is 

recommended that this is done automatically by incorporating a 

suitable timeswitch in the supply to the unit.  The use of Heatrae 

Sadia accessory no. 95 970 124 is recommended 

for units rated 

up to 3kW.

  The timeswitch can then be set to switch the unit 

on for a suitable period to allow it to heat up before it is next to 

be used.  NOTE: A timeswitch must be capable of switching the 

required resistive load. 

Summary of Contents for SUPREME 220SS

Page 1: ...1 SUPREME 220SS 250SS 310SS 560SS Fitting Instructions and User Guide...

Page 2: ...d physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazard...

Page 3: ...not be switched on It must be left to thaw and must then be thoroughly inspected to ensure it is totally thawed and undamaged 1 9 The unit is not suitable for installation in an area where a water jet...

Page 4: ...r use with the wall If unsuitable due to wall type provide alternative fixings 3 0 INSTALLATION TAPS 3 1 Remove the tap bezel by unscrewing the 2 screws Check that tap boss thread and bore are clean R...

Page 5: ...y vent pipe is used the pipe must terminate below the unit in a safe visible position After connection DO NOT make soldered joints in the pipework close to the heater as the heat may damage the connec...

Page 6: ...handle is just loose With the handle in the vertical off position remove locking screw spring washer and security tab line up the hole in the plastic tap cap with the hole beneath it by gently turning...

Page 7: ...Y BEFORE REMOVING THE COVERS AND CARRYING OUT ANY OF THE FOLLOWING ACTIONS DO NOT BYPASS ANY SAFETY CONTROLS Any faults that cannot be identified using the Fault Finding chart or in case of doubt cont...

Page 8: ...it board 560 master control 95 615 002 13 Circuit board 560 auxiliary control 95 615 003 14 Wiring harness 4way inc diodes 95 612 006 15 Wiring harness 220 250 complete 95 612 007 Wiring harness 310 c...

Page 9: ...m of the stroke the handle will push over a gentle feature and remain open when released To move back to the off position no flow gently lift the handle To select option 1 or 2 with the handle in the...

Page 10: ...drawn off and discarded NOTES GUARANTEE This Supreme water heater is guaranteed for a period of two years from the date of purchase provided 1 The unit has been installed in accordance with these ins...

Page 11: ...574 Parts Center Network 65 Business Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co uk Newey Eyre Specialists Products Division Please contact your local branch...

Reviews: