4.0
INSTALLATION – MOUNTING THE WATER HEATING UNIT
4.1
The Aquatap water heating unit is free standing and must be positioned on a level
surface. If being mounted in a cupboard, shelf unit or false base, ensure that the
supporting surface can carry the full weight of the unit (see TECHNICAL
SPECIFICATIONS section 2.0, page 4)
4.2
Refer to fig. 1, page 4 for dimension details of the Aquatap water heating unit and the
relative positions of the water and electrical connections.
4.3 The Aquatap heater unit must be located beneath the dispensing tap.
It must be possible to connect the flexible hoses and electrical connection cable from the
dispensing tap to the OUTLET and VENT connections on the Aquatap unit. The pipes
must not be lengthened. The dispenser tap can be positioned so it discharges into a sink
or mounted on its own purposed designed drip tray (available as an accessory, product
code 95970138).
4.4
Sufficient room should be left around the unit to allow access for maintenance and
servicing (see fig. 1, page 4). Two of the case fixing screws are located on the top
rear edge of the unit; it must be ensured that these can be accessed in order to facilitate
removal of the front cover for maintenance and servicing. An ambient temperature
between 5ºC and 35ºC is required in the cupboard housing the Aquatap water heating
unit. Air circulation must be provided so air can flow through the cupboard (see diagram
below). If adequate air circulation is not provided this will cause calibration problems
and the Aquatap water heating unit will not function correctly.
4.5
The Aquatap water heating unit is supplied with a moulded plug fitted to a 1.2 metre
electrical supply cable. If the cable needs to be lengthened this must be completed by a
qualified electrician. Refer to section 9.0, page 14 - INSTALLATION – ELECTRICAL
REQUIREMENTS for full details of the electrical installation.
8
Summary of Contents for Aquatap Boil and Ambient
Page 1: ...Aquatap Boil and Chill Boil and Ambient Installation and user manual...
Page 21: ...21 FIGURE 15 EXPLODED VIEW FOR STEAM TRAP REMOVAL AND DESCALING...
Page 25: ...25 1 1 FIGURE 16 EXPLODED VIEW OF DISPENSER 1 3 2 4 1 1 1...
Page 26: ...26 FIGURE 17 EXPLODED VIEW HEATER ASSEMBLY 14 12 16 10 13 15 11 17 18 21 20 45 21 21 18 46...
Page 27: ...27 FIGURE 18 EXPLODED VIEW HEATER ASSEMBLY 22 25 25 26 27 9 24 23 38 50...
Page 28: ...FIGURE 19 EXPLODED VIEW HEATER 28 29 30 31 9 28...
Page 29: ...29 32 FIGURE 20 EXPLODED VIEW HEATER...
Page 33: ...33 NOTES...
Page 34: ...34 NOTES...
Page 35: ...35 NOTES...