13.0 FAULT FINDING - AQUATAP HEATER
22
SYMPTOM
POSSIBLE CAUSE
ACTION
No Indicator lights on
heater
1. If no water or heat - no power
to unit
2. if hot water available - no
power to indicators lights
1. Check power supply is correctly connected
and switched on. Check primary cut-out
has not operated
2. Check wiring harness to indicator lights is
plugged into control PCB
Heater does not fill on
commissioning
Power light flashing
two pulses
1. If POWER on indicator is not
lit - no power to unit
2. Water supply not turned on
3. Solenoid valve fault
4. Low water pressure
5. Inlet pipe blocked
1. Check power supply is correctly connected
and switched on. Check primary cut-out
has not operated
2. Check water supply
3. Check solenoid operation, replace if
necessary
4. Check water is turned on and supply
pressure exceeds minimum requirements,
0.5 bar
5. Check inlet pipe filter is not obstructed
Heater does not heat
up on commissioning
Power light flashing
three pulses
1. If POWER on indicator is not
lit - no power to unit
2. Element fault LED 3 on PCB
flashing
1. Check power supply is correctly connected
and switched on. Check primary cut-out
has not operated
2. Check heating element
Heater does not fill
after commissioning
Power light flashing
two pulses
1. Level sensor fault
2. Solenoid valve fault
3. Electronic control PCB fault
4. Low water pressure
5. Inlet pipe blocked
1. Check level sensor earth connection
2. Check solenoid operation, replace if
necessary
3. Check all connections to the control PCB,
replace if necessary
4. Check water is turned on and supply
pressure exceeds minimum requirements
5. Check inlet pipe filter is not obstructed
Heater does not heat
up after commisioning
Power light flashing
three pulses
1. Element fault - LED 3 on PCB
flashing
2. Electronic control PCB fault
3. Control thermistor fault -
short circuit - LED 4 on PCB
flashing
1. Check element operation, if faulty replace
2. Check all connections to the control PCB,
replace if necessary
3. Check continuity
Water flow from vent
and primary cut-out
operates
1. Solenoid valve fault
2. Level sensor fault
3. Electronics control PCB fault
4. Inlet pipe blocked
1. Check solenoid operations, replace if
necessary
2. Check level sensor earth connection
3. Check all connections to the control PCB,
replace if necessary
4. Check inlet pipe filter is not obstructed
Summary of Contents for Aquatap Boil and Ambient
Page 1: ...Aquatap Boil and Chill Boil and Ambient Installation and user manual...
Page 21: ...21 FIGURE 15 EXPLODED VIEW FOR STEAM TRAP REMOVAL AND DESCALING...
Page 25: ...25 1 1 FIGURE 16 EXPLODED VIEW OF DISPENSER 1 3 2 4 1 1 1...
Page 26: ...26 FIGURE 17 EXPLODED VIEW HEATER ASSEMBLY 14 12 16 10 13 15 11 17 18 21 20 45 21 21 18 46...
Page 27: ...27 FIGURE 18 EXPLODED VIEW HEATER ASSEMBLY 22 25 25 26 27 9 24 23 38 50...
Page 28: ...FIGURE 19 EXPLODED VIEW HEATER 28 29 30 31 9 28...
Page 29: ...29 32 FIGURE 20 EXPLODED VIEW HEATER...
Page 33: ...33 NOTES...
Page 34: ...34 NOTES...
Page 35: ...35 NOTES...