3.

 

Functionality of the electric heating element 

 

a.

 

Dryer. The 

temperature of the heating agent is adjusted with “+” and “

-

“ switches: 4 levels from 30 °C to 60 °C

 

b.

 

Space heater. 

The temperature of the room is adjusted with “+” and “

-

“ switches: 8 levels from 17 °C to 24 °C.

 

Functionality is available in the configuration with the external temperature sensor.  

c.

 

Controller  switches  the  heating  element  off  when  the  window  is  opened.  Functionality  is  available  in  the 
configuration with the external open door/ window sensor.  

d.

 

Weekly and daily programmer with possibility of setting 3 time zones per day 

 only in configuration with the 

mobile application.   

e.

 

The dryer mode function with the possibility of setting the operating time: 

timer „

START

” –

 after max 4 hours the electric heating element switches off, 

timer „TURBO” –

 after max 4 hours the electric heating element returns to the previous setting, 

timer „

DELAY

” –

 switching the device on with the delay max. 8 hours 

 operating time max. 4 hours. 

f.

 

„HOLIDAY”

 mode 

 the possibility to quick decrease set temperature to the lowest level: 17

˚C for the room and 

30˚C for the radiator –

 functionality is available in configuration with the mobile application.  

g.

 

Parental control

” –

 the possibility of lock the keyboard from the mobile application.  

h.

 

Energy consumption meter  

 functionality is available in configuration with the mobile application. 

i.

 

Intelligent visualisation of operating modes: heating, setting, timer, failure 

 colourful LED technology. 

j.

 

The 

controller may be rotated by 330°.

 

k.

 

Intelligent operation control 

 microprocessor-based control. 

l.

 

Protection against agent freezing 

 Antifreeze function. 

m.

 

Three-level thermal protection.  
- the regulation controller prevents the temperature from exceeding 6

0 °C.

 

- in case of an uncontrolled temperature increase, the thermal fuse cuts out the power if any damage of the 
regulator or temperature sensor occurs. 
- protection of the heating element against "operating in a dry radiator", meaning operating outside the radiator 
or  operating  on  the  radiator  without  any  heating  agent  inside.  In  case  of  a  sudden  temperature  rise,  the 
electronic 

system applied in the controller switches off the heating element at 87˚C, above which the single

-

usage thermal fuse actuates. 
 

n.

 

The  application  of  advanced  electronics  at  the  “operating”  mode  and  the  electronics  of  Ultra

-Low-Power 

Technology at the “stand

-

by” mode provides the low power consumption.

 

 

V.

 

NEX 1.0 

 how to use the device 

 

 

 

Buttons: 
   S1 

 ON/OFF 

   S2 

 decrease temperature 

   S3 

 increase temperature 

   S4 

 connection with NEX 

Signalling 
   L1 

 operating conditions 

   L2 

 temperature and time setting 

   L3 

 switched on timer 

   L4 

 communication with external appliances 

   L5 

 communication with NEX 

Reviews: