background image

CAUTION

All  electrical  connections  must  be  done  by  a  qualifi ed  electrician  and 
according to the local electrical codes. Always cut off the unit’s main 
power whenever the access panel is open or removed. Always install the 
machine  outdoors  (unless  otherwise  approved  by  the  manufacturer), 
while respecting the minimal clearances needed for proper operation 
and heating.

!

CAUTION

Proper  pool  chemistry  is  vital  to  the  life  of  your  heater.  Pay  particular 
attention to the total alkalinity and TDS. It is highly recommended that you 
have your pool chemistry checked often by an independent pool store.

!

5

OWNER’S MANUAL

Summary of Contents for pool heat pump

Page 1: ...OWNER S Manual PRINTED IN CANADA 10 2009...

Page 2: ......

Page 3: ...10 Electrical Connections 11 Wiring Diagram 12 Service Analyzer Control 13 Operation 14 Caring for your Pool Heater 15 Initial Startup 16 Meaning of Display Codes 17 Troubleshooting 18 Requesting Assi...

Page 4: ...ed the HEATPRO pool heat pump has a lower heating capacity on a BTU hr basis Therefore it needs to operate for a longer time to accomplish the desired results Occasionally it may be necessary to run t...

Page 5: ...r Please also record the purchase date of your device and your dealer s name address and telephone number Model Number ____________________________________________________ Serial Number_______________...

Page 6: ...e CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in material damage particularly to the pro...

Page 7: ...lways install the machine outdoors unless otherwise approved by the manufacturer while respecting the minimal clearances needed for proper operation and heating CAUTION Proper pool chemistry is vital...

Page 8: ...he very least all around your heat pump The use of 90 degree bends and short radius elbows in the water piping should be kept to a minimum Mount the unit on a sturdy base preferably a concrete slab or...

Page 9: ...n withstand high pressure The installation of a heat pump bypass is not necessary unless the water flow exceeds 75 GPM Note Certain installations have valves which isolate the heat pump from the water...

Page 10: ...ment All electric and metal components must then be bonded to each other and then to the copper rod CAUTION 1 A 1 3 lb check valve must be installed between the heater and any automatic chlorine distr...

Page 11: ...Bonding and Plumbing diagram Fig 2 Fig 3 Heat Pump Chemical feeder 9 OWNER S MANUAL...

Page 12: ...SPA mode can be controlled with an external switch to heat up to 80 degrees Internal mode Use the P_S mode on the main menu External mode Open contact POOL mode Closed contact SPA mode Control using a...

Page 13: ...knock out located on the left or the right side of the base and then insert it in the control box The electrical diagram is located on the lid of the control box as well as in this manual WARNING Gro...

Page 14: ...ensor High pressure switch Closed OK Opened high pressure Low pressure switch Closed OK Opened low pressure Flow switch Closed flow Opened no flow Orange 240 Vac or Red 208 Vac 24 Vac compressor conta...

Page 15: ...n Fahrenheit degrees 13 Temperature and parameter display Celsius or Fahrenheit mode Access to parameters To raise the desired temperature or to change parameters To lower the desired temperature or t...

Page 16: ...rogram press the SET key until you see P_S and by press ing one of the arrow keys you can switch to POL or SPA Once the heating mode has been programmed it will be displayed for five seconds and will...

Page 17: ...Caring for your Pool Heater How to protect your pool heater 15 OWNER S MANUAL...

Page 18: ...water temperature you desire The fan will immediately start The compressor will start after a 3 to 4 minute delay When the compressor is running the HEATING CHAUFFAGE indicator located on the right se...

Page 19: ...ckwash filter and or heater The unit will show HP3 after 3 HP faults This will stop your heater for protection Po Water temperature probe connected to WS on the electronic board may be disconnected If...

Page 20: ...is not Pool pump is not running Filter is dirty restricting the water flow Turn the pool pump on Backwash and clean filter The heater is displaying o and it will not start Heat pump control set to OF...

Page 21: ...nsation It is normal to see condensation dripping under the heater To check if the water really is a leak you must stop the heater and leave the pool pump running for over 5 hours If water is still co...

Page 22: ...ll your dealer It may save you the cost of a service call If you still need help follow the instruc tions below Service can be obtained by calling one of these phone numbers CANADA 1 888 238 7665 USA...

Page 23: ...ust turn the breaker off The unit must be drained of all its water You will need to disconnect the IN and OUT water connections Then the unit must be tilted or blown out with air until all water is ou...

Page 24: ...the normal intended use of the unit or acts of God This warranty is void if the product is repaired or altered in any way by any persons or agencies other than those authorized by HAYWARD and is in l...

Page 25: ...cture date and applies only if the product is installed according to the HAYWARD specifications This warranty does not include the repair of damage due to negligence accident freezing installation in...

Page 26: ...24 Notes OWNER S MANUAL...

Page 27: ......

Page 28: ......