12
11
Slimline
Series
Model
: PRT-E
Comfort Levels Explained
The thermostat provides Weekday/Weekend or 7 Day Programming options.
You should consult the “Optional Features” section to select the required mode.
The thermostat is supplied with comfort levels already programmed, but these can be
changed easily. The default times and temperatures are;
08.00 - 21°C (Wake) 09.30 - 16°C (Leave) 16.30 - 22°C (Return) 23.00 - 17°C (Sleep)
If you only want to use 2 levels, you should program the unused levels to
--.--
Note: For Weekday/Weekend programming, the 4 comfort levels are the same for all
weekdays but can be different for the weekends.
For 7 Day programming, each day can have 4 different comfort levels.
•
To program comfort levels, press Clock once ............................................................
For 7 Day programming,
only Mon is displayed
in the day indicator field.
For Weekday/Weekend programming,
Mon Tue Wed Thu Fri
are displayed on screen.
Temperature Display
This thermostat can be setup to use an air sensor, floor sensor or both.
The display will clearly show which sensor is being controlled by showing either:
Note: Built in air sensor only MUST NOT be used to control electric underfloor heating.
Floor sensor only or built in air & floor sensor together must be used.
When the thermostat is set to use both sensors, the room temperature will be displayed.
To view the floor temperature, press and hold the key until the Floor Temp is
displayed on screen.
Room Temperature
Floor Temperature
Summary of Contents for PRT-E1
Page 1: ...1 Model PRT E Model PRT E...