Section Header
24
12V
Feature 07 – Floor Temp Limit:
This function is available when mode 07 is set to 03 or 04.
You can set a floor limiting temperature between 20-45°C (28°C is the default setting).
Note: Air Sensor only MUST NOT be used to control electric under-floor heating.
Floor Sensor or Both should be used.
Feature 08 – Optimum Start:
Optimum start will delay the start up of the heating
system to the latest possible moment to avoid unnecessary heating and ensure
the building is warm at the programmed time. The thermostat uses the rate of
change information to calculate how long the heating needs to raise the building
temperature 1°C (with a rate of change of 20, the thermostat has calculated the
heating needs 20 minutes to raise the building temperature 1°C) and starts the
heating accordingly.
Feature 09 – Rate of Change:
Number of minutes for 1°C temperature rise.
Feature 10 –
Not used on this model.
Feature 11 –
Not used on this model.
Feature 12 – Program Mode:
Non-Programmable, Weekday/Weekend (5/2),
7 Day Programming or 24 Hour. The thermostat offers three programming modes and the
option of configuring it to work as a non-programmable thermostat.
Weekday/ Weekend -
allows you to program 4 comfort levels for the weekday and
4 different comfort levels for the weekend.
7 Day Program Mode -
Each day has 4 comfort levels that can be programmed
independently.
24 Hour Mode -
All days are programmed the same and repeat continuously.
Feature 13 - Temperature Format:
This function allows you to select between °C and °F.
Summary of Contents for neoStat
Page 1: ...12V...
Page 2: ...2 Series Model 12V Available in Sapphire Black and Glacier White...
Page 7: ...Section Header 6 12V 1 2 3 4...
Page 11: ...Section Header 10 12V 12V 10 Mode 1 Thermostat 12V...
Page 12: ...11 Series Section Header 2 3 1 4 6 7 8 5 15 14 12 11 9 10 13...
Page 32: ...31 Series Section Header 1 4 5 2 10 7 9 3 8 Series 31 6 Mode 2 Time Clock Series...
Page 37: ...36 Notes 12V...
Page 38: ...Model Manual REF 37 Notes 37 Series...
Page 39: ...38 Notes 12V...