Section Header
26
12V
Optional Settings - Feature Table
01
02
03
04
05
06
07
08
09
10
11
12
13
FEATURE
Pairing
Switching Differential
Frost Protection Temperature
Output Delay
Up/Down Temperature Limit
Sensor Selection
Floor Temperature Limit
Optimum Start
Rate of Change
Not used on this model
Not used on this model
Program Mode
Temperature Format
DESCRIPTION
Used to add zone to the neoHub
00 = 0.5°C
01 = 1.0°C (Default)
02 = 2.0°C
03 = 3.0°C
07° - 17°C (12°C = Default)
00 - 15 Minutes (00 = Default)
00° - 10°C (00 = Default)
00 = Built in Sensor (Default)
01 = Remote Air Sensor
02 = Floor Sensor Only
03 = Built in & Floor Sensor
04 = Remote Air & Floor Sensor
20°C - 45°C (28°C = Default)
00 - 05 Hours (00 = Default)
Minutes to raise by 1°C
00 = Non - Programmable
01 = Weekday/Weekend (Default)
02 = 7 Day Programming
03 = 24 Hour Mode
00 = °C, 01 = °F (00 = Default)
SETTING