Optional Settings - Feature Table
P3
P2
P1
01
Menu
Entry Point
02
03
04
05
06
07
08
09
10
11
12
13
FEATURE
Failsafe
Pairing to UH8-RF
Pairing to RF-Switch
Pairing to Hub
Switching Differential
Frost Protection Temperature
Output Delay
Up/Down Temperature Limit
Sensor Selection
Floor Temperature Limit
Optimum Start
Rate of Change
Not used on this model
Not used on this model
Program Mode
Temperature Format
DESCRIPTION
00 = Disabled
01 = Enabled (Default)
00 – 99 = Receiver address/zone no. & type
Commences countdown from 99 – 00 seconds.
Used to add zone to the neoHub/neoHub Mini
00.5 = 0.5˚C
01 = 1.0°C (Default)
02 = 2.0°C
03 = 3.0°C
07° - 17°C (12°C = Default)
00 - 15 Minutes (00 = Default)
00° - 10°C (00 = Default)
00 = Built in Sensor (Default)
01 = Remote Air Sensor
02 = Remote Floor Sensor
03 = Built in Sensor & Remote Floor
20°C - 45°C (28°C = Default)
00 - 05 Hours (00 = Default)
Minutes to raise by 1°C
00 = Non - Programmable
01 = Weekday/Weekend (Default)
02 = 7 Day Programming
03 = 24 Hour Mode
00 = °C, 01 = °F (00 = Default)