background image

22

21

WiFi 

Series

Model:  

DT-ETS WiFi RF

THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES

NEED NOT BE ADJUSTED

Feature 01 – Temperature Format: 

This function allows you to select between °C or °F.

Feature 02 - Switching Differential: 

This function allows you to increase the switching 

differential of the thermostat. The default is 1°C which means the thermostat will 

switch the heating on 1°C below the set temperature and will turn it off when the set 

temperature is achieved. With a 2°C differential, the heating will switch on 2°C below the 

set temperature and will switch off when the set temperature is achieved.

Feature 03 - Frost Protect: 

You can set whether the thermostat will maintain the frost 

temperature when the thermostat display is turned off. As a default, this is enabled.

Feature 04 – Frost Protect Temperature: 

This is the temperature maintained when the 

thermostat is in frost mode. The range is 07-17°C. The default is 12°C and is suitable for 

most applications.

Feature 05 – Output Delay: 

To prevent rapid switching, an output delay can be entered. 

This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.

Feature 06 – Not used on this model.

Optional Features Explained

Feature 07 – Receiver Address: 

Within one building, up to 32 RC2-W receivers can 

be used. Each receiver must have a unique address.

Feature 08 – Not used on this model.

Feature 09 – Not used on this model.

Feature 10 – Fail Safe: 

If enabled, the thermostat will send a signal to the receiver 

every 20 minutes. Should the receiver fail to receive two signals, the receiver will 

activate the output for 20% of the time. This is to protect the system against a loss of 

wireless signal and in case the thermostat battery fails whilst you are away.

Feature 11 – Temperature Up/Down Limit:

 This function allows you to limit the use 

of the up and down keys. This limit is also applicable when the thermostat is locked 

and so allows you to give others limited control over the heating system.

Feature 12 – Air Sensor Selection: 

On this thermostat, you can select which sensor 

should be used. Built in sensor or remote air sensor.

Feature 13 – Floor Limit Temperature: 

This function allows you to set a maximum 

floor temperature in order to protect the floor surface from overheating. 

Summary of Contents for DT-ETS WiFi RF

Page 1: ...1 Model DT ETS WiFi RF Model DT ETSWiFi RF...

Page 2: ...WiFi Setup Security Types and Compatibility Remote Access Via App Remote Access Via Web Browser Temperature Display Pairing with the RC2 W Clean Screen 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Locki...

Page 3: ...able with the temperature You won t have to adjust the thermostat further Any adjustment above this setting will waste energy and cost you more money Room thermostats need a free flow of air to sense...

Page 4: ...the bottom face of the thermostat Step 2 Place the thermostat front somewhere safe Terminate the thermostat as shown in the diagrams on pages 28 29 of this booklet Step 3 Screw the thermostat back pla...

Page 5: ...is established 6 Room Temp Indicates the current temperature sensor mode 7 Set Displayed when the target temperature is adjusted 8 Clean Screen Freezes screen temporarily to enable cleaning 9 Cancel U...

Page 6: ...order for local and remote access to operate and you must set this up manually Log into your wireless router and navigate to the LAN settings page Find and select the DHCP setup details This should d...

Page 7: ...N DISABLED not recommended W E P lowest security level Your choice of security settings in the thermostat must match the setting in your router Often you will find WPA and WPA2 are a single option in...

Page 8: ...you should create a new service within your router Within this service you must open TCP port 8068 Use the port forwarding function to forward the new service to the IP address of your WiFi thermosta...

Page 9: ...k feature 07 has been configured correctly Comms LED To pair the thermostat with the RC2 W receiver follow these steps On the receiver Press and hold the Pairing button until the Comms LED lights up O...

Page 10: ...ner of the display again for 10 secs Clean Screen Pressing will disable all keys providing you 15 seconds to wipe the screen clean before the keys are re activated Keypad Lock Indicator The keys under...

Page 11: ...frost mode the flame symbol will be displayed To cancel the frost protect mode press the key once The heating is indicated ON when the flame icon is displayed When the flame icon is absent there is n...

Page 12: ...an output delay can be entered This can be set from 00 15 minutes The default is 00 which means there is no delay Feature 06 Not used on this model Optional Features Explained Feature 07 Receiver Addr...

Page 13: ...08 09 10 11 12 13 FEATURE Temperature Format Switching Differential Frost Protect Frost Protection Temperature Output Delay Not used on this model Receiver Address Not used on this model Not used on...

Page 14: ...onfigure the new temperature Press DONE to confirm the new temperature Press the ON key once to turn the thermostat back on Re calibrating the Thermostat The thermostat has a reset function to restore...

Page 15: ...efer to the appropriate diagram for connections to your heating system Remote Air Probe If Fitted Mains Supply From Fused Spur DT ETS WiFi RF N L RT2 230VAC Room Sensor Error Codes E0 The internal sen...

Page 16: ...ETS WiFi RF Notes Floor Probe Fit in tubing Mains Supply 230V 16 Amps Mains supply must be fused correctly Floor Sensor RC2 W R LOAD L R N N 230VAC Live Neutral Matting Wiring Diagram DT ETS WiFi RF...

Page 17: ...ll our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com PDF FAQ Heating Professionals Request a copy of our product installation guide contai...

Reviews: