22
21
WiFi
Series
Model:
DT-ETS WiFi RF
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES
NEED NOT BE ADJUSTED
Feature 01 – Temperature Format:
This function allows you to select between °C or °F.
Feature 02 - Switching Differential:
This function allows you to increase the switching
differential of the thermostat. The default is 1°C which means the thermostat will
switch the heating on 1°C below the set temperature and will turn it off when the set
temperature is achieved. With a 2°C differential, the heating will switch on 2°C below the
set temperature and will switch off when the set temperature is achieved.
Feature 03 - Frost Protect:
You can set whether the thermostat will maintain the frost
temperature when the thermostat display is turned off. As a default, this is enabled.
Feature 04 – Frost Protect Temperature:
This is the temperature maintained when the
thermostat is in frost mode. The range is 07-17°C. The default is 12°C and is suitable for
most applications.
Feature 05 – Output Delay:
To prevent rapid switching, an output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 06 – Not used on this model.
Optional Features Explained
Feature 07 – Receiver Address:
Within one building, up to 32 RC2-W receivers can
be used. Each receiver must have a unique address.
Feature 08 – Not used on this model.
Feature 09 – Not used on this model.
Feature 10 – Fail Safe:
If enabled, the thermostat will send a signal to the receiver
every 20 minutes. Should the receiver fail to receive two signals, the receiver will
activate the output for 20% of the time. This is to protect the system against a loss of
wireless signal and in case the thermostat battery fails whilst you are away.
Feature 11 – Temperature Up/Down Limit:
This function allows you to limit the use
of the up and down keys. This limit is also applicable when the thermostat is locked
and so allows you to give others limited control over the heating system.
Feature 12 – Air Sensor Selection:
On this thermostat, you can select which sensor
should be used. Built in sensor or remote air sensor.
Feature 13 – Floor Limit Temperature:
This function allows you to set a maximum
floor temperature in order to protect the floor surface from overheating.