background image

 6 

MANTELS, SURROUNDS & TRIM INSTALLATION 

WITHOUT HOOD

WITH HOOD 

Note:

  The stated installation clearances provide the safest distance for combustible materials to ensure that walls, ceil-

ings, and mantle components will not be affected by heat discoloration, warping, or possible fire.  Each appliance installa-
tion presents a different set of variables which can create problems beyond the control of the gas log manufacturer.  It is 
the responsibility of the installer to stay within the minimum clearances stated and set forth by the manufacturer within this 
instruction manual. 

 

The firebox is shipped with a 2 ¾” hood. Loosen screws and slide the hood into place and tighten screws to hold hood. 
Heatmaster, LLC. has an optional 4” hood to replace the standard 2 ¾” hood.  Contact your local dealer for details. 
NOTE:  The hood provided with this firebox must not be modified or replaced with another hood or canopy that is not sup-
plied or approved by HM/AGL, LLC.     

The firebox may be finished in an infinite number of ways from rustic to contemporary using marble, stone, wood, brick, 
tile or various other natural or man-made materials.

 

CAUTION: 

 THE BLACK PAINTED FACE OF THE FIREBOX (EXCLUDING NAIL FLANGES) MUST NOT BE  

 

COVERED WITH COMBUSTIBLE MATERIALS.  SOME MAN-MADE BRICKS OR STONES MAY 

 

CONTAIN COMBUSTIBLE MATERIAL.

 

All noncombustible materials, which overlap the black painted face, must be sealed to the firebox face with a high quality 
heat-resistant caulk adhesive or sealant.  The edges should also be sealed to act as a fire-stop.

 

This firebox is a universally listed Ventless Firebox Enclosure.  For mantel clearances and noncombustible material re-
quirements when installing a decorative type unvented room heater, see below.  The dimensions noted with “min” are the 
minimum dimensions that are allowed.  Failure to meet the clearance requirements will void your warranty and may result 
in a fire hazard. 

The firebox is shipped with a 2 ¾” hood. Loosen screws and slide the hood into place and tighten screws to hold hood. 
Heatmaster, LLC. has an optional 4” hood to replace the standard 2 ¾” hood.  Contact your local dealer for details. 
NOTE:  The hood provided with this firebox must not be modified or replaced with another hood or canopy that is not sup-
plied or approved by HM/AGL, LLC.     

HVF36-BB & HVF42-BB 

Mantel Clearance and Noncombustible Material 

Summary of Contents for HVF36-BB

Page 1: ...ON INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE VENT FREE FIREBOX MODEL HVF36 BB HVF42 BB INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR USE ONLY WITH LISTE...

Page 2: ...cal building officials to assure compliance with local regulations and codes and to obtain any required permits A qualified installer or service agency must perform installation and service All instru...

Page 3: ...panels or surrounds shall not seal ventilation openings in the fireplace 7 Make sure to leave adequate clearances for accessibility for purposes of servicing and proper operation 8 Combustible floorin...

Page 4: ...NCES COMBUSTIBLE SIDE WALL INSTALLATION COMBUSTIBLE SIDE WALL PLACEMENT HVF36 BB FOR HVF36 BB HVF42 BB COMBUSTIBLE SIDE WALL INSTALLATION HVF42 BB GUIDELINE DIMENSIONS FOR CORNER APPLICATION HVF36 BB...

Page 5: ...3 8 Framing dimension for width 38 1 4 44 1 4 Framing dimension for Depth 24 3 4 24 Fireplace Model Inner Dimensions HVF36BB HVF42BB Height of rear wall 22 22 1 2 Width of front opening 29 1 2 35 1 2...

Page 6: ...ick tile or various other natural or man made materials CAUTION THE BLACK PAINTED FACE OF THE FIREBOX EXCLUDING NAIL FLANGES MUST NOT BE COVERED WITH COMBUSTIBLE MATERIALS SOME MAN MADE BRICKS OR STON...

Page 7: ...e line also The tapping must be accessible for test gauge connection immediately upstream of the gas supply connection to the unit Use a soap water solution or a liquid gas leak detector to coat each...

Page 8: ...RONT BOTTOM HVFBB36 02 14 HVFBB42 02 18 1 11 OUTER CAP BRACE HVFBB 02 18 HVFBB 02 18 3 12 COVER PLATE HFB 02 13 HFB 02 13 1 13 THERMODISC 11 1395 11 1395 1 HOOD NOT SHOWN HVFBB36 02 25 HVFBB42 02 25 1...

Page 9: ...ng or other delivery to Heatmaster LLC American Gas Log LLC shall be borne by the purchaser The mailing address is Heatmaster LLC American Gas Log LLC 3625 Benson Rd Angier NC 27501 3 Along with the p...