HeatLink HEP025RT Installation, Operation And Maintenance Manual Download Page 7

7

®

Heat

Link

www.heatlink.com

HEP025RT

Installation, Operation, and Maintenance Manual

L6HEP025RT

#

Components

Component Description

Part Number (Qty.)

HEP025RT

1

Single wall, brazed-plate heat 

exchanger

The heat exchanger provides separation of the 

primary and secondary loops.

n/a

2

Primary pump

The pump moves the heated fluid through the 

hydronic system when there is a call for heat 

from the thermostat. Factory set to 3rd speed. 

See pump curves below.

PUMP1558

3

Secondary pump

PUMP1558

4

Electrical box

Houses relays and wiring.

n/a

5

Timer

Circulates fluid for 15 minutes every 24 hours.

n/a

6

Terminal block

Provides easy access wiring for thermostats, flow 

switch (opt.), and aux. contacts.

n/a

7

24Vac 20VA plug-in transformer

Provides power to the panel electronics.

PLINTR20VA

8

½" Safety relief valve

For pressure relief only. Furnished without a lever. 

1/2" female drain. Pressure range 75-175psi (5.17-

12.06 bar). Setting 50, 75, 125 and 150psi (3.45, 

5.17, 8.61 and 10.34 bar).

This protects the system from thermal expansion 

pressure buildup during times when reducing 

valve thermal expansion bypass is ineffective due 

to high inlet water pressure.

n/a

9

Pressure gauge

The rear connection pressure gauge reads the 

secondary loop pressure. May not be exactly as 

shown.

Range: 0-60psi

n/a

10

Automatic air vent

Automatic air vent purges air trapped in the 

secondary loop. May not be exactly as shown.

79932

11

Drain and fill valve

Access point for filling and draining the panel.

n/a

12

Optional flow switch

The electronic flow indicator provides DHW 

priority when the DHW flow rate reaches a factor 

pre-set level (approx. 0.5 US gpm). Must be 

piped in downstream of panel.

FLWSWTCH

13

Accessory pack

Panel installation accessories.*

n/a

i Mounting screw

Panel mounting screws.

(×4)

ii ¾" Nitrile washer

Washers for installation of adapters, plus (4) 

spares.

NTRWSH34 (×10)

iii ¾" MBSP × ¾" FNPT adapters Adapters for expansion tank, and pressure relief 

piping.

(×2)

iv ¾" isolation valve

Zone valve used to isolate the panel from the 

system during fill & purge, and maintenance.

(×4)

14

Optional cover

Powder coated cover 

PC2319CVR

*Contact your HeatLink representative if the accessory pack is missing in whole or in part.

Panel Components

Summary of Contents for HEP025RT

Page 1: ...M Jul 18 2017 Max Pres 125psi 862kPa Volts 120 24 VAC Serial XXX XXXX Phase Freq 1 60 Cycles Max Temp 100C 212F Amps Maximum 15 3189472 1 adaptor Type UPS 15 58 CIL2 115 V 60 Hz 8 F P N 97948357 PC 1...

Page 2: ......

Page 3: ...ademarks in this material are property of the respective companies HeatLink and the HeatLink logotype are trademarks of HeatLink Group Inc All rights reserved L6HEP025RT Table of Contents HEP025RT Ins...

Page 4: ...injury or death Prior to commencing installation of this panel it is necessary to read and understand all sections of this manual The symbols below are used throughout this document to ensure proper...

Page 5: ...ve occurred during shipping If damage is visible notify your courier and supplier immediately Step 2 Open the carton by removing the staples Step 3 Remove the cardboard spacers from the carton then re...

Page 6: ...8 2017 Max Pres 125psi 862kPa Volts 120 24 VAC Serial XXX XXXX Phase Freq 1 60 Cycles Max Temp 100C 212F Amps Maximum 15 3189472 1 adaptor Type UPS 15 58 CIL2 115 V 60 Hz 8 F P N 97948357 PC 1131HLK I...

Page 7: ...m thermal expansion pressure buildup during times when reducing valve thermal expansion bypass is ineffective due to high inlet water pressure n a 9 Pressure gauge The rear connection pressure gauge r...

Page 8: ...relief Adjustable range 50 175psi 3 45 12 06 bar The Series 530C and LF530C is ideal for bypass thermal expansion pressure relief Power supply pre wired on system controller 120 V ac max current 2A Pr...

Page 9: ...e Step 7 See page 14 for optional flow switch installation instructions Prior to mounting the panel ensure the wall is capable of supporting the weight of the panel Ensure that a 120V receptacle is wi...

Page 10: ...ng disconnect power supply M A D E I N C A N A D A CAUTION WARNING Consult Manual Before Use AVERTISSEMENT Consulter le manual avant l usage HeatLink Group Inc 4603E 13th Street NE Calgary Alberta Can...

Page 11: ...res 125psi 862kPa Volts 120 24 VAC Serial XXX XXXX Phase Freq 1 60 Cycles Max Temp 100C 212F Amps Maximum 15 3189472 1 adaptor Type UPS 15 58 CIL2 115 V 60 Hz 8 F P N 97948357 PC 1131HLK IP42 TF 95 Ma...

Page 12: ...meet local codes and jurisdictions Wiring to the terminal strip requires 18 gauge wire Do not exceed 2VA per thermostat Do not cross terminals C and R W R C 24 V Signal W R C 24 V 24 V Signal W R C Si...

Page 13: ...ternal contacts of the thermostat open the auxiliary contacts open and the pumps stop Note If the FLWSWTCH optional DHW priority flow switch 5 is installed and the DHW flow is above the factory settin...

Page 14: ...ead sealant and fittings connect the water heater output to the input on the flow switch and house hot water system to output on flow switch The straight in and outlet pipe in front of and behind the...

Page 15: ...e wiring is done properly Consult qualified electrician prior to alteration of wiring between heat source and panel Output of heat source is unable to meet demand of heating system Compare output of h...

Page 16: ...nts expansion tanks pressure relief valves etc for heat source as per local codes Use isolation ball valves for all circuits and components Local codes regulations and authorities have final jurisdict...

Page 17: ...Heat Link www heatlink com Panel Line Name Installation Operation and Maintenance Manual...

Page 18: ...Heat Link www heatlink com Panel Line Name Installation Operation and Maintenance Manual...

Page 19: ......

Page 20: ...Fax 1 866 450 1155 China Distributed by Cathay Links International Phone 852 25693213 Fax 852 25359271 Ireland Distributed by Jamoni Ltd Phone 057 932 4062 Fax 057 932 4063 Freephone 1800 311338 M xi...

Reviews: