INTRODUCTION
1 Instructions guidance
1.1
Product documentation
The instructions are an integral part of the appliance and must
be handed to the user on completion of the installation in order
to comply with the current regulations.
• Carefully read and understand the manual, which will enable
you to complete your task of installing or servicing this
appliance safely. No liability can be accepted in the event of
damage for not complying with the guidance in this instruction
manual.
These instructions consist of, Installation, Servicing, Fault Finding,
Replacement of Parts and Spares. The instructions are an integral
part of the appliance and must, to comply with the current issue of
the Gas Safety (Installation and Use) Regulations, be handed to the
user on completion of the installation.
1.2
Associated documents
- 1 magnetic lighting instruction label
- 1 guarantee envelope pack
- 1 wall template
1.3
Explanation of symbols
a
DANGER: Risk of injury.
e
DANGER: Risk of electric shock.
ATTENTION: Risk of damage to the appliance or
to its surroundings.
IMPORTANT: Important information.
1.4
Guarantee registration
Thank you for installing a new Heatline appliance in your home.
Heatline appliances are manufactured to the very highest
standard so we are pleased to offer our customers a
Comprehensive 12 month Guarantee, with the option to extend it
to two years.
We recommend you complete and return as soon as possible
your guarantee registration card. If your guarantee registration
card is missing you can obtain a copy or record your registration
by telephoning the Heatline Customer Service number 0844 736
9138.
2 Appliance description
2.1
Safety devices
Overheating Safety Device
The appliance is designed to recognise the potential of an
overheat situation and will shutdown before a potentially
dangerous situation occurs.
Safety discharge valve
A safety discharge valve and discharge pipe are fi tted to the
boiler. This valve must not be touched.
- The heating safety valve opens when the pressure in the
heating circuit exceeds 3bar.
• Should there be any discharge from the pipe, which should
terminate in a safe place outside the property, isolate the
boiler’s electrical supply and call your Installer, Service
Engineer or Heatline’s Service Department.
Frost protection
The appliance has a built in frost protection device that protects
the boiler from freezing. With the gas and electric supplies
ON and irrespective of any room thermostat setting, the frost
protection device will operate the pump when the temperature of
the boiler water falls below 8
O
C.
A timer is used so that the temperature can be checked
periodically. After 10 minutes the pump will be stopped if the
temperature is higher than 10
O
C or has already reached 35
O
C.
The burner will activate if the boiler temperature does not reach
10
O
C after 30 minutes or at any time if the temperature drops to
5
O
C.
The burner will switch off when the temperature reaches 35
O
C.
The frost-protection system is active when the appliance is
switched on.
The boiler controls cannot ensure that the installation is
fully protected against frost. Any exposed pipes should be
adequately protected and particular attention should be paid to
condensate drains. An additional frost thermostat may also be
required.
a
Your domestic water circuit (hot or cold) is not
protected by the boiler controls.
Condensate drain blockage
During freezing conditions this may be due to the forming of
ice in the condense drain external to the house. In this case, a
safety device shuts down the appliance.