69
Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Installation Manual • 2619-983 Rev. U • 9/22
Removing Fixed Glass Assembly
1. Remove the decorative front.
2. The glass assembly has two upper spring latches
and two lower spring latches. See Figure 11.2. Lo
-
cate the two spring latches that are on the upper left
and right of the fireplace.
3. Pull upper spring latch on one side forward to release
glass assembly while supporting glass assembly with
opposite hand. Repeat for the other upper spring
latch always taking care to support the glass assem
-
bly with one hand.
4. Grasp glass on the upper right and left sides and
remove glass assembly by lifting “up” and “out”.
Note:
Observe the presence of a space or gap between
the glass latch and the front of the appliance where the
bottom of the glass assembly is positioned. This gap is
designed for positive placement when replacing the glass
assembly. See Figure 11.2.
Replacing Fixed Glass Assembly
The bottom glass latches have been designed to create
a small gap between the glass clip and the face of the
appliance. See Figure 11.2.
1. Install the bottom of the glass assembly so that the
two tabs on the bottom of the glass latch engage the
gap. By tilting the top of the glass towards the face of
the appliance, tension will be applied to the bottom
two glass latches. Use one hand to support the glass
at all times.
2. Fasten the two upper glass latches, one at a time, by
pulling out and downward into position on the glass
assembly. Use one hand to support the glass at all
times.
3. Verify that the top two glass latches are engaged by vi
-
sually verifying that glass latches have engaged both
left and right tabs on the glass frame.
4. Verify the bottom two glass latches have engaged the
glass frame tabs by grasping the bottom of the glass
frame assembly and pulling the glass frame assembly
“away” from the face of the appliance and “release”
the glass frame. The spring action of the clips will
“pull” the glass frame assembly towards the face of
the appliance if bottom clips are properly engaged. If
the glass frame assembly does not pull back towards
the face of the appliance, repeat steps 1-4.
H. Fixed Glass Assembly Removal and Re-
placement
WARNING!
Risk of Asphyxiation!
Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
•
DO NOT
strike, slam or scratch glass.
•
DO NOT
operate fireplace with glass removed, cracked,
broken or scratched.
•
Replace as a complete assembly.
G. IntelliFire Touch
®
Control System Setup
• Detailed instructions for electrical wiring and connec
-
tions are provided in Section 8.
• Determine if this appliance is equipped with a Module
Reset Switch. See Section 8. Verify this switch is in
the ON position.
• Verify that the 3-Position switch on the IFT-ECM is
switched to the REMOTE position. Detailed Operating
Instructions for the IFT-ECM are provided in Section
3.K of the Owner’s Manual.
Figure 11.1 IFT-ECM
3 POSITION SWITCH
TOP VIEW
LED INDICATOR
If this appliance is being upgraded to an optional
Intel-
liFire Touch
Remote Control, and/or optional power vent,
fan, or light kit are added as new accessory upgrade(s)
to fireplace:
1. The RC400 remote will need to be paired to the ECM.
2. Follow the installation instructions provided with the
IntelliFire Touch
remote and/or accessory kit(s).