Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Installation Manual • 2619-983 Rev. U • 9/22
14
B. Appliance Location and Clearances to
Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls
and allow suf
-
ficient clearance for heat management systems venting.
See Figure 3.6.
WARNING!
Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.6 Appliance Locations
A
E
A
C
TOP VENT
ONE 90
0
ELBOW
ALCOVE
INSTALLATION
D*
TOP VENT
ONE 90° ELBOW
B
F
Refer to Section 10.C for mantel and wall
projection information.
Consider the mantel or cabinet system to be
installed and comply with the necessary
requirements for elevated hearth. Refer to
instructions included with cabinet system.
18 in. (457 mm) required
when Passive Heat Side
Discharge Kit is installed.
1/2 IN.
It is acceptable to install the Passive Heat Front Discharge Kit
with a corner installation.
A
B
C
D
E
F
RAVE32-IFT-B
Inches
42-7/8
37
60-5/8
See Section 10.C for Alcove Installation
(Mantel and Wall Projection).
14-5/8
17-1/4
Millimeters
1089
940
1541
371
438
RAVE36-IFT-B
Inches
46-3/8
42
65-1/2
16-3/8
17-1/4
Millimeters
1178
1067
1664
416
438
RAVE42-IFT-B
Inches
51-3/8
49
72-5/8
18-3/4
17-1/4
Millimeters
1305
1245
1845
476
438
Note:
Adjust framing dimensions for interior chase sheathing (such as sheetrock).