11/04
4031-478 Rev i
3
NOVUS PLUS INSTALLATION INSTRUCTIONS
1. U.S. and Canada Certification
The Novus Plus has been tested in accordance with the
ANSI
standards Z21.50-2000 and Z21.47-1998
in the United
States, the current
CSA 2.22-2000
and
CGA 2.3-M98
in
Canada, and has been listed by Underwriters Laboratories
Inc. for installation as described in this manual. All components
are UL, AGA, CGA or CSA safety certified.
2. Local Codes
This installation must conform with local codes. In the absence
of local codes, comply with the
National Fuel Gas Code ANSI
Z223.1-latest edition
in the U.S., and the
CAN/CGA B149,
Installation Codes
in Canada.
If you need assistance during installation, contact your local
dealer or the Heatilator Technical Services Dept., Hearth &
Home Technologies Inc. (HHT), 1915 W. Saunders St., Mt.
Pleasant, IA 52641, 1-877-427-8368.
HEATILATOR® is a registered trademark of Hearth & Home
Technologies, Inc.
3. Efficiency
The efficiency rating of the appliance is a system thermal
efficiency rating determined under continuous operating
conditions and was determined independently of any installed
system.
Tools and building supplies normally required for
installation:
Saw
Framing Material
Pliers
Surround
Hammer
Caulking Material
Phillips Screwdriver
Gloves
Tape Measure
Framing Square
Plumb Line
Electric Drill and Bits
Level
Safety Glasses
Wall-finishing Materials
Non-corrosive Leak Check Solution
A. GAS APPLIANCE SPECIFICATIONS
Note:
Minimum and maximum clearances must be
maintained at all times. Illustrations throughout these
instructions reflect typical installations and are for design
purposes only. Actual installation may vary slightly due
to individual design preferences.
The illustrations and diagrams used throughout these
installation instructions are not drawn to scale.
4. Glass Specifications/Certifications
Heatilator gas appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures
as defined by the CPSC. The tempered glass has been tested and certified to the requirements of
ANSI Z97.1-1984
and
CPSC 16
CFR 1202
. (Safety Glazing Certification Council
SGCC# 1595
and
1597
. Architectural Testing, Inc. Reports
02-31919.01
and
02-
31917.01
).
This statement is in compliance with
SPCS 16 CFR Section 1201.5
“Certification and labeling requirements” which refers to
15 USC 2063
stating, “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer
to whom the product is delivered.”
Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this
requirement is available from the factory. Please contact your dealer or distributor to order.
5. Novus Plus Nomenclature
#
g
o
l
a
t
a
C
n
o
i
t
p
i
r
c
s
e
D
S
U
L
P
I
6
3
2
4
B
N
t
o
l
i
P
t
n
e
t
t
i
m
r
e
t
n
I
h
t
i
w
e
c
n
a
il
p
p
A
s
a
G
l
a
r
u
t
a
N
6
3
2
4
a
e
r
A
g
n
i
w
e
i
V
.
n
i
6
3
-
6
3
,
s
n
o
i
s
n
e
m
i
D
g
n
i
m
a
r
F
.
n
i
2
4
-
2
4
L
I
s
a
G
e
n
a
p
o
r
P
,
n
o
i
t
i
n
g
I
t
o
l
i
P
t
n
e
t
t
i
m
r
e
t
n
I
WARNING!
This appliance is tested and listed for use only with the optional accessories listed in these instructions. Use of
optional accessories not specifically tested for this appliance could void the warranty and/or result in a safety hazard.