NOVUS DIRECT VENT INSTALLATION INSTRUCTIONS
A. APPLIANCE SPECIFICATIONS
Note:
Minimum and maximum clearances must be
maintained at all times. Illustrations throughout these
instructions reflect typical installations and are for design
purposes only. Actual installation may vary slightly due
to individual design preferences.
The illustrations and diagrams used throughout these
installation instructions are not drawn to scale.
Tools and building supplies normally required
for installation:
Saw
Wall-finishing materials
Pliers
Framing material
Hammer
Surround
Phillips screwdriver
Caulking material
Tape measure
Gloves
Plumb line
Framing square
Level
Electric drill and bits
Safety glasses
Non-corrosive leak check solution
3. Glass Specifications/Certifications
Heatilator gas appliances manufactured with tempered glass may be installed in hazardous locations such as
bathtub enclosures as defined by the CPSC. The tempered glass has been tested and certified to the requirements
of
ANSI Z97.1-1984
and
CPSC 16 CFR 1202
. (Safety Glazing Certification Council
SGCC# 1595
and
1597
. Architectural
Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
SPCS 16 CFR Section 1201.5
Certification and labeling requirements which
refers to
15 USC 2063
stating Such certificate shall accompany the product or shall otherwise be furnished to any
distributor or retailer to whom the product is delivered.
Some local building codes require the use of tempered glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory. Please contact your dealer or distributor to order.
1. U.S. And Canada Certification
The NOVUS Series Gas Appliance has been tested in accordance with the
ANSI standard
Z21.88-2002
in the
United states, the current
CSA 2.33-2002
in Canada, and has been listed by Underwriters Laboratories Inc. for
installation as described in this manual. All components are UL, AGA, CGA or CSA safety certified.
2. Local Codes
This installation must conform with local codes. In the absence of local codes you must comply with the
National
Fuel Gas Code, ANSI Z223.1-latest edition
in the U.S.A. and the
CAN/CGA B149 Installation Codes
in Canada.
The Novus Series gas appliance has been tested and listed for use in manufactured housing (mobile homes).
These installation instructions conform with the
Manufactured Home Construction and Safety Standard
,
Title 24
CFR, Part 3280
, or when such a standard is not applicable, the
Standard for Manufactured Home Installations
,
ANSI A225.1
.
For assistance during installation contact your local dealer or contact the Heatilator Technical Services Department,
Hearth & Home Technologies, 1915 W. Saunders Street, Mt. Pleasant, Iowa 52641, 1-800-927-6841.
HEATILATOR
®
and NOVUS are registered trademarks of Hearth & Home Technologies Inc.
WARNING!
This appliance is tested and listed for use only with the optional accessories listed in
these instructions. Use of optional accessories not specifically tested for this appliance
could void the warranty and/or result in a safety hazard.
Æ