Heatilator • ICON DV • 4042-300 Rev R • 06/07
7
In addition to these framing
dimensions, also reference the
following sections:
• Clearances and
Mantel
Projections
(Sections 3.C. and 3.D.)
• Vent Clearances and
Framing
(Section
6)
Top Vent
One 90° Elbow
Horiz Term
Top Vent
One 90° Elbow
Horiz Term
A
A
D
C
E
B
B
1-1/2 in. (38 mm)
min.
appliance
to combustibles
Alcove
Installation
F
A
Drywall
Note:
• Illustrations
re
fl
ect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
• Around air openings.
• For service access.
Locate appliance away from traf
fi
c areas.
WARNING
A. Select Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (See Figure 3.1).
Note:
For actual appliance dimensions refer to
Section 16.
Figure 3.1 Appliance Locations
3
3
Framing and Clearances
Model #
A
B
C
D
E
F
ICON60I
in.
47-1/2
64-1/4
30-1/2
48-1/2
90-7/8
48
mm
1207
1632
775
1232
2309
1219
ICON100I
in.
61-1/2
74-1/8
30-1/2
62-1/2
104-7/8
48
mm
1562
1883
775
1588
2665
1219