38
Heatilator • GNTC50 • 4002-095 Rev H • 06/07
C. Junction Box Installation
Remove the junction box assembly from the valve compart-
ment.
If the box is being wired from the
OUTSIDE
of the appli-
ance:
• Loosen the two screws on the Romex connector, feed
the necessary length of wire through the connector and
tighten the screws.
• Make all necessary wire connections to the receptacle and
assemble the receptacle and cover to the junction box.
• Attach the junction box assembly to the outside of the
appliance with the two screws provided.
RED
BLACK
WHITE
Ground
Figure 10.3 Junction Box Detail
If the box is being wired from the
INSIDE
of the appliance:
• Pull the electrical wires from outside the appliance through
this opening into the valve compartment.
• Loosen the two screws on the Romex connector, feed
the necessary length of wire through the connector and
tighten the screws.
• Make all necessary wire connections to the receptacle and
assemble the receptacle and cover to the junction box.
• Attach the junction box assembly to the inside of the
appliance with the two screws provided.
If the box is not wired at the time of appliance installation,
assemble the receptacle and cover to the box and install on
the inside of the appliance.
14-3 with ground Romex is the recommended wiring
to the appliance junction box. This allows the outlet
for the fan to be powered independently from other
accessories.
14-3 with ground
Romex
Break the tab
between the two
hot connectors