22
32912 Rev L
10/03
GENEVA SERIES B-VENT GAS APPLIANCE
N. LOG REMOVAL/REPLACEMENT
1.
Remove/open the control access panel as shown in Figures 11 and 12 on page 11.
2.
For removal of the grate/log assembly remove two screws (one per side) from the hearth pan. See Figure 32.
3.
Lift up on the assembly to remove it from the appliance and set it aside, being careful not to damage any of the logs.
See Figure 33.
4.
Reverse the order to reinstall the logs.
Figure 32
Unscrewing the Log/Grate Assembly
from the Hearth Pan
Figure 33
Log/Grate Assembly Removal