GENEVA SERIES B-VENT GAS APPLIANCE
6. Intermittent Pilot Ignition
a. Appliance Requirements
1)
This appliance is equipped with an intermittent
pilot control valve which operates on a 3 volt
system. See wiring diagram, Figure 14.
2)
The appliance is supplied with a battery pack
and a 3-volt AC transformer, which requires
the installation of the supplied junction box.
We highly recommend that the junction box
be installed at this time to avoid reconstruc-
tion. The battery pack requires two D cell bat-
teries (not included). Batteries cannot be
placed in the battery pack while using the 3
volt AC transformer. Conversely, the trans-
former must be unplugged if the battery pack
is used.
b. Optional Accessories Requirements
Wiring for optional accessories should be done
now to avoid reconstruction.
Note:
This appliance must be electrically wired
and grounded in accordance with local codes
or, in the absence of local codes, with
National
Electric Code ANSI/NFPA 70-latest edition
or
the
Canadian Electric Code, CSA C22l.1
.
Figure 14 - Intermittent Pilot Ignition Wiring Diagram
7. Standing Pilot Ignition
a. Appliance Requirements
A wiring diagram is shown in Figure 15.
b. Optional Accessories Requirements
Wiring for optional accessories should be done
now to avoid reconstruction.
Figure 15 - Standing Pilot Ignition Wiring Diagram
Optional Junction Box Wiring
BLACK
WHITE
GROUND
14-2 with
Ground Romex
WARNING!
Standing pilot appliance does NOT require a
110V AC supply for operation. Connecting the
appliance/wall switch to a 110V AC supply will
cause the appliance to malfunction and destroy
the valve and thermopile.
CAUTION:
Battery polarity must be correct or control
module damage will occur.