10/03
32912 Rev L
17
GENEVA SERIES B-VENT GAS APPLIANCE
2. Standing Pilot Ignition
A.
This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING
smell all around the appliance area for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbors phone. Follow the suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
C.
Use only your hand to turn the manual shutoff valve. Never use tools. If the knob will not push in or turn by hand,
dont try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control system and any gas control which as been under
water.
WARNING!
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY READ BEFORE OPERATING
STANDING PILOT LIGHTING INSTRUCTIONS
To Turn off the Gas to the Appliance
1. Turn off the wall switch.
2. Remove/open control access panel.
3
.
Turn manual shutoff valve to CLOSED position. Do
not force.
4. Replace/close control access panel.
1. Turn the wall switch to the appliance to the OFF
position.
2. Remove/open control access panel.
3.
Turn manual shutoff valve to CLOSED. Wait 5
minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP!
Follow B in the safety information above on this
label. If you dont smell gas, go to the next step.
4.
Turn manual shutoff valve to OPEN.
5.
Turn pilot knob clockwise to OFF. Knob may have
to be depressed to pass the PILOT position.
6.
Locate pilot assembly inside appliance.
7.
Locate red ignitor button.
8. Turn pilot knob to PILOT and push in.
9. Continue to hold in pilot knob and push the red ignitor
button 12-15 times until small blue pilot flame
appears.
10. Continue to hold in pilot knob for approximately one
minute. Pilot should remain lit. If pilot goes out, wait
5 minutes and repeat Steps 4-9.
11
.
To light the main burner, release and turn the knob
counterclockwise to ON. If the appliance is connected
to a wall switch, turn it to ON.
Do not
light by hand.
12
.
If the appliance will not operate, follow the instructions
TO TURN OFF THE GAS TO THE APPLIANCE and
call your service technician or gas supplier.
3, 4
Manual
Shutoff Valve
7
Push Button
Ignitor
5, 11
Valve
6
Pilot Assembly