![Heatilator EHS3633 Owner'S Manual Download Page 31](http://html1.mh-extra.com/html/heatilator/ehs3633/ehs3633_owners-manual_2116994031.webp)
Heatilator • Eclipse • 4049-300 Rev H • 11/07
31
BLACK
WHITE
GROUND
14-2 with
Ground Romex
Figure 10.5 Junction Box Detail
14-2
with ground Romex is the recommended
wiring to the appliance junction box.
E. Junction Box Installation
• Remove the junction box assembly from the valve
compartment by removing the one screw securing the
assembly to the outer shell.
• Rotate the front of the assembly in while sliding the rear
of the assembly forward and out of the retaining slot. See
Figure 10.4.
Screw Out
Figure 10.4 Remove Junction Box Assembly
• Pull wire through hole that junction box mounts in on outer
shell.
• Knock out appropriate hole in junction box and install
Romex connector.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections to the receptacle and
assemble the receptacle and cover to the junction box.
• Reattach the junction box.