7065-132I • May 18, 2017
39
www.heatilatorecochoice.com
1. There are 4 pre-drilled holes in the flue collar 90 degrees
apart. Attach the flue collar to the appliance pipe/liner.
If the seal is questionable use appliance mastic
Figure
39.1.
2. Attach gasket to bottom side of flue collar with a thin coat
of silicone.
Flue Collar
Stove Pipe/Liner
Gasket
Figure 39.1
Figure 39.2
Figure 39.3
Figure 39.4
In some installations the flue collar and appliance pipe/liner
do not always align properly. This situation may be remedied
by using the optional offset adapter. See Appliance Dimen-
sions page for the amount of distance this accessory can
telescope between the flue collar and appliance pipe/liner.
1. Remove the cast iron flue collar from the appliance and
flip it upside down. Using the larger #7 drill bit supplied,
drill through all 8 countersunk locations.
Figure 39.2.
2. Slide the gasket over the the flue collar and attach it to the
offset adapter using the 8-32 flathead screws provided.
Figure 39.3.
3. Adjust the offset adapter to desired distance. Drill holes
through the lower chamber as shown in
Figure 39.4
using
the small drill bit #26 provided.
4. Cut the gasket to the proper length and slide in between
the upper and lower chambers centered on the screw
holes. Attach the upper and lower chambers with screws
provided.
Figure 39.5
.
5. Repeat the process on the bottom side.
Cast Iron Flue Located on Appliance
Drill through all 8 countersunk
locations
Once distance is established, drill holes
and secure both chambers together.
Figure 39.5
B. Securing Appliance Pipe/Liner to Flue Col-
lar
C. Optional Offset Adapter Installation