background image

Page  1

7056-153C

September 14, 2015

Eco-Choice WS Series Wood Burner Installation Instructions

Eco-Choice WS Series Wood Burner Installation Instructions

INSTALLATIONS TO COMPLY WITH AS/NZS2918:2001 

AND WILL REQUIRE A BUILDING CONSENT

IMPORTANT: Read all instructions carefully before starting installation.  Failure to follow these 

instructions may result in a 

fi

 re hazard and will void the warranty.

• 

Fig. 3,4,5,6, 7 and Table 1,2,3,4 relate to installations with tested 

fl

 ue systems; as per 

AS/NZS 

2918:2001 - Appendix F

, with a ceiling angle between 0° - 30° inclusive.

• 

For installations with a ceiling angle greater than 30°, refer to Fig. 7 & 8 and 

AS/NZS 2918:2001 

4.6.3(b)

• 

Ceiling Plate may vary in size depending on ceiling angle.  Please specify ceiling pitch prior to 
ordering the ceiling plate.

• 

Heatilator Eco Choice series wood burner’s are tested and approved to the N.Z. National Environ-
mental Standards;

WS18-AU Eco-Choice Hardwood Certifi ed 

Particulate Emissions = 1.3 g/kg Space Heating Ef

fi

 ciency = 85%

WS18-AU Eco-Choice Softwood Certifi ed 

Particulate Emissions = 1.1 g/kg Space Heating Ef

fi

 ciency = 73%

WS22-AU Eco-Choice Hardwood Certifi ed

Particulate Emissions = 1.2 g/kg Space Heating Ef

fi

 ciency = 82%

WS22-AU Eco-Choice Softwood Certifi ed

Particulate Emissions = 1.3 g/kg Space Heating Ef

fi

 ciency = 66%

Model:

WS22-AU

Model:

WS18-AU

Summary of Contents for Eco-Choice WS18-AU

Page 1: ...ve For installations with a ceiling angle greater than 30 refer to Fig 7 8 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitch prior to...

Page 2: ...HAMOISTURECONTENTLESSTHEN25 dry basis WetbacksareNOTanapprovedoptionandmustnotbefitted Hearth HomeTechnologies 1445NorthHighway Colville WA 99114 UnitedStatesofAmerica OVERALLAVERAGEEFFICIENCY TESTEDT...

Page 3: ...3 Side View 12 1 2 in 317mm 25 in 635mm C L 19 11 16 in 500 mm 21 11 16 in 550 mm 29 in 736 mm 14 13 16 in 376 mm 9 9 16 in 242 mm 13 13 16 in 350 mm 19 1 16 in 484 mm 9 5 16 in 236 mm 26 1 2 in 673m...

Page 4: ...imum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 1 2 A Floor Protector can include ceramic tiles with grouted...

Page 5: ...ont width 692 F Min overall floor protector depth 1379 Table 2 Fig 5 1 If a separate floor protector is being used position now Place the firebox on the floor protector to suit the minimum installatio...

Page 6: ...e 6 3 Side View 26 in 660mm 13 in 330mm C L 9 9 16 in 243mm 13 13 16 in 351mm 34 in 864mm 9 13 16 in 249mm 19 1 16 in 484mm 14 13 16 in 376mm 19 5 8 in 499mm 21 11 16 in 551mm 11 5 8 in 295mm 6 5 8 in...

Page 7: ...tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 3 4 A Floor Protector can inc...

Page 8: ...floor protector front width 688 F Min overall floor protector depth 1377 Table 4 Fig 8 1 If a separate floor protector is being used position now Place the firebox on the floor protector to suit the...

Page 9: ...Code E2 Acceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the...

Page 10: ...casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing...

Page 11: ...of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7 ADD Cowl AS NZS2918 2001 Un...

Page 12: ...ral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower onto the appliance The Flue Mounted Shield...

Page 13: ...ON IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MOD...

Page 14: ...coverage under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor which...

Page 15: ...t supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or 9 inte...

Page 16: ...phone Notes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow thes...

Reviews: