Page 8
7056-153C
September 14, 2015
WS Series Wood Burner
CORNER POSITIONING (45°)
DESCRIPTION
Default Flue Kit
with
fl
ue shield
A
Min. clearance from
fi
rebox corner to corner walls
75
B
Min. distance from center of spigot to corner walls
393
C
Min. distance from corner wall to
fl
oor protector front
1217
D
Min.
fl
oor protector projection from corner wall
731
E
Min.
fl
oor protector front width
688
F
Min. overall
fl
oor protector depth
1377
Table 4
Fig. 8
1. If a separate
fl
oor protector is being used position now. Place the
fi
rebox on the
fl
oor protector to
suit the minimum installation clearances. (See Fig 7 or 8)
2. Seismically restrain the
fi
rebox and the
fl
oor protector to the
fl
oor.
3. Fit 2 x 6mm
fi
xings suitable for the
fl
oor material. DO NOT over tighten.
4. Fit timber trim pedestal edging to front and back of base (optional).
A
B
D
E
F
C
FLOOR PROTECTOR
CORNER W
ALL
CORNER W
ALL
CORNER POSITIONING (45°)
FIREBOX INSTALLATION