Heatilator ECO-ADV-PS35 Installation Manual Download Page 26

 26 

 

 

 

 

                     7058-205A  

 

 

 

 

         6/16/2014

HEATILATOR ECO-CHOICE

Service Parts

Beginning Manufacturing Date: Apr 2010 

Ending Manufacturing Date: Active

ECO-ADV-PS50

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. 

Hearth and 

Home Technologies does not sell directly to consumers

. Provide model number and serial number when 

requesting service parts from your dealer or distributor.

Stocked

at Depot

Item

Description

Comments

Part Number

ACCESSORIES

Collar, Offset, Top Vent

812-3570

Damper ,3"

For Tall Vertical 

Runs Only

PEL-DAMP3

Y

Damper, 4"

PEL-DAMP4

Outside Air Kit, 3"

OAK-3

Outside Air Kit, 2"

811-0872

Hose, Alum Flex, 2 Inch X 3 Ft

3 Ft

200-0860

Outside Air Cap Assembly

7001-044

Outside Air Collar Assembly

7001-045

Trim Plate, Outside Air Kit

412-7100

Smart-Batt Il

841-0970

Smart-Stat Il

841-0960

Thermostat, Mechanical

812-3760

Y

Thermostat, Programmable

811-0520

Top Vent Adapter

TPVNT-5

Vent Adapter, 3-4"

811-0720

Vent Adapter, 90, Cleanout

811-0610

Fastener Packs

AVK Rivnut Repair Kit 1/4 -20 & 3/8-16 Rivnut Tools

RIVNUT-REPAIR

Y

Bolt, Hex Head

Pkg of 10

25221A/10

Y

Guide Pin Sleeve

Pkg of 25

31120/25

Y

Nut SER FL SMALL 1/4-20

Pkg of 24

226-0130/24

Y

Nut,  2-WY SIDE-LOCK JAM 3

Pkg of 24

226-0100/24

Y

Nut, Lock 1/4-20

Pkg of 25

226-0090/25

Y

Screw HWH MS 1/4-20 X3/4 NS

Pkg of 25

220-0080/25

Y

Screw PH PHL TC 8-32X1/2

Pkg of 25

220-0030/25

Y

Screw, Wing Thumb, 8-32X1/2

Pkg of 24

7000-223/24

Y

SMS #8 X 1/2 S-GRIP BO

Pkg of 40

12460/40

Y

Thumb Screw 1/4-20 x 3/4

Pkg of 10

844-5070

Washer, 1/4 SAE

Pkg of 24

28758/24

Y

Washer, SAE

Pkg of 25

227-0080/25

Y

Summary of Contents for ECO-ADV-PS35

Page 1: ...soline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING CAUTION Tested and approved for wood pellets Burning of any other type of fuel voids you...

Page 2: ...2 Getting Started 4 A Design Installation Location Considerations 4 B Thermostat Wall Control Location 5 C Tools And Supplies Needed 5 D Inspect Appliance and Components 5 E Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearances to Combustibles UL and ULC 10 C Hearth Pad Requirements UL and ULC 10 4 Vent Information 11 A Venting Termination Minimum Requirements 11 ...

Page 3: ...llowing actions C Glass Specifications This stove is equipped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please contact your dealer for replacement glass D Electrical Rating on high Model PS35 115 VAC 60 Hz Start 3 8 Amps Run 1 3 Amps Model PS50 115 VAC 60 Hz Start 5 1 Amps Run 3 0 Amps Model CAB50 115 VAC 60 Hz Start 5 1 Amps Run 3 0 Amps E Mobile Home Approved This applianc...

Page 4: ...ce Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney offsets Place the appliance where there will be a clear passage for a Listed chimney through the ceiling and roof vertical or through exterior wall horizontal Installing the required outside air kit will affect the location of the vent termination When...

Page 5: ...ermostat Wall Control Location The thermostat wall control s location will have some affect on the appliance s operation Maximum wire length from appliance is 100 feet 30 48m continuous unspliced wire Recommended 20 gauge wire solid copper When located close to the appliance it may require a slightly higher temperature setting to keep the rest of the house comfortable When located in an adjacent r...

Page 6: ...nstalled and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in non combustible areas Verified all clearances meet installation manual requirements Mantels and wall projections comply with installation manual requirements Protective hearth strips and hearth extension installed per manual requirements Appliance Setup Section 5 Pg 21 All packagi...

Page 7: ...de View with Top Vent Adapter 22 1 4 in 565mm 2 3 8 in 60mm 8 3 4 in 223mm 22 15 16 in 583mm 24 13 16 in 630mm 31 3 4 in 806mm 20 1 4 in 514mm 28 in 711mm 9 11 16 in 247mm 20 3 4 in 527mm MODEL ECO ADV PS35 4 3 8 in 111mm 3 1 8 in 79mm 30 7 8 in 784mm 28 3 4 in 730mm C L 3 Dimensions and Clearances A Appliance Dimensions ...

Page 8: ...1 Top View Figure 8 3 Side View Figure 8 4 Side View with Top Vent Adapter 2 3 8 in 60mm 9 3 4 in 248mm 24 1 4 in 616mm 26 7 16 in 672mm 28 5 16 in 719mm 35 3 4 in 908mm 32 in 813mm 20 1 4 in 514mm 10 11 16 in 272mm 22 3 4 in 578mm 4 3 8 in 111mm 3 1 8 in 79mm 31 7 8 in 810mm 29 3 4 in 756mm C L ...

Page 9: ... 2 Front View Figure 9 1 Top View Figure 9 3 Side View Figure 9 4 Side View with Top Vent Adapter 24 1 2 in 622 mm 23 3 4 in 603 mm 36 1 2 in 927 mm 4 3 8 in 111 mm 3 1 8 in 79 mm 30 1 8 in 765 mm 28 in 711 mm 2 3 8 in 60 mm 9 in 228 mm 26 7 8 in 681 mm 25 7 8 in 657 mm ...

Page 10: ...icated Mea sure front distance M from the surface of the glass door Hearth Pad Requirements Inches Millimeters K Sides 2 51 L Back 2 51 M Front 6 152 Straight Back Against Wall Inches Millimeters A Back Wall to Appliance 2 51 B Side Wall to Appliance 14 356 Corner Installation Inches Millimeters C Walls to Appliance 2 51 Installations with 3 to 3 inch Top Vent Adapter Vertical Installation Inches ...

Page 11: ...s and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in Above grass top of plants wood or any other com bustible 12 in 36 in no OAK Clearance from any forced air intake of other appli ance 12 in Clearance horizontally from combustible wall ...

Page 12: ...all as the exhaust vent outlet and located lower on the wall than the exhaust vent outlet The outside air supply kit can supply most of the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult...

Page 13: ... especially during lighting and die down of the fire Considerations for successful draft include Preventing negative pressure Location of appliance and chimney WARNING Risk of Asphyxiation Negative pressure can cause spillage of combustion fumes and soot E Chimney and Exhaust Connection 1 Chimney Connector Use 3 or 4 inch 76 102mm diameter type L or PL venting system It can be vented vertically or...

Page 14: ...29m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe calculated previously and the altitude above sea level of this installation Figure 14 2 a Locate the calculated equivalent feet of pipe on the vertical left side of the chart b Move to the right horizontally on...

Page 15: ...of additional vertical vent Horizontal sections of vent pipe should have a 1 4 inch 6 35mm rise per foot Hearth Home Technologies recommends any installation requiring more than two 90 elbows or more than 15 feet 4 5m of venting to use 4 inch 102mm vent NOTICE These are guidelines for successful venting of your pellet appliance The more vertical rise you can obtain in your system the better it wil...

Page 16: ... than 48 inches 1 2m horizontally from c Not less than 12 inches 305mm above 3 Distance from permanently closed windows a Not less than 12 inches 305mm below horizontally from or above 4 Distance between bottom of termination and grade should be 12 inches 305mm minimum This is conditional upon plants in the area and nature of grade surface The grade surface must be a non combustible material i e r...

Page 17: ...F Mantel Depth n a n a 36 914 Model PS50 Minimum Maximum Inches Millimeters Inches Millimeters A Height 56 3 4 1441 n a n a B Width 53 1346 n a n a C Depth n a n a 48 1219 D Side Wall 14 356 n a n a E Top 16 533 n a n a F Mantel Depth n a n a 36 914 Model CAB50 Minimum Maximum Inches Millimeters Inches Millimeters A Height 56 3 4 1441 n a n a B Width 53 1346 n a n a C Depth n a n a 48 1219 D Side ...

Page 18: ...stallation instructions for all reduced air clearances installations D Vertical into Existing Class A Chimney Firestop Flashing Rain Cap 6 in 152mm Minimum Non combustible Hearth Pad 3 in 76mm Minimum Cleanout Cover 12 in 305mm Minimum Ceiling Support 6 in 152mm Flue Connector 6 in 152mm Class A Chimney Connector Adapter 3 in to 6 in 76 152mm Top Vent Kit Non combustible Hearth Pad Clean out Cover...

Page 19: ... the termination cap is 6 inches 152mm there is the possibly of soot build up around the termination area If this occurs we suggest to move the termination further away from the house to prevent it The suggested mini mum is 12 inches Straight Out 6 in 152mm Minimum Non combustible Hearth Pad Wall Thimble Horizontal Termination Cap 2 in 51mm Minimum 6 in 152mm Minimum From Glass 45 Degree Wall Thim...

Page 20: ...nimum Fireclay Flue Liner with Airspace Concrete Cap Fire Risk Inspection of Chimney Masonry chimney must be in good condition Meets minimum standard of NFPA 211 Factory built chimney must be a minimum 6 inch 152mm UL103 HT WARNING Non combustible Hearth Pad Airtight Clean Out Door Clean Out cover Sheathing 3 in 76mm Minimum 1 in 25mm Clearance Flashing Fireclay flue Liner with Airspace Concrete C...

Page 21: ...or your installation if using the 3 inch kit 1 Measure distance from floor to air vent opening in appli ance and mark location on wall Use saw to cut opening in wall 2 inch kit Cut a 2 1 2 to 3 inch opening on inside wall and a 3 to 3 1 2 inch opening on outside of house 3 inch kit Cut a 3 1 2 to 4 inch opening on inside wall and a 4 to 4 1 2 inch opening on outside of house 2 Use wire tie or hose...

Page 22: ...tlet using the 2 holes already in the short horizontal pipe in the top vent adapter as a guide Install the 2 screws Figure 22 1 6 Install the vent pipe into the top vent adapter be sure to silicone all joints 7 To clean the top vent adapter open the clean out cover Figure 22 1 Silicone Rear Exhaust Outlet 3 to 6 inch Offset Adapter 3 to 3 inch Offset Adapter Use Hole on Each Side as Drilling Guide...

Page 23: ...te readings The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air NOTE If the thermostat is located too close to the appliance you may need to set the temperature setting slightly higher to maintain the desired tem perature in your home 3 There is a 4 screw terminal block located on the back lower left corner of the stove directly above the pow...

Page 24: ...d HUD CFR 3280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 24 1 CAUTION Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Do NOT cut th...

Page 25: ...01 044 Outside Air Collar Assembly 7001 045 Trim Plate Outside Air Kit 412 7100 Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y Thermostat Programmable 811 0520 Top Vent Adapter TPVNT 5 Component Pack SRV7058 054 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Fastener Packs AVK Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head Pk...

Page 26: ...ly 7001 044 Outside Air Collar Assembly 7001 045 Trim Plate Outside Air Kit 412 7100 Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y Thermostat Programmable 811 0520 Top Vent Adapter TPVNT 5 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Fastener Packs AVK Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head Pkg of 10 25221A 10 Y Gu...

Page 27: ...y 7001 045 Trim Plate Outside Air Kit 412 7100 Outside Air Kit 3 OAK 3 Reset Button Assembly SRV7000 040 Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y Thermostat Programmable 811 0520 Top Vent Adapter TPVNT 5 Touch Up Paint 812 0910 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Fastener Packs Avk Rivnut Repair Kit RIVNUT REPAIR Y Bolt Hex Head 1 4 20 ...

Page 28: ...4 Division of HNI INDUSTRIES Please contact your Heatilator Eco Choice dealer with any questions or concerns For the number of your nearest Heatilator dealer log onto http www heatilatorecochoice com This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the foll...

Reviews: