10
7058-205A
6/16/2014
HEATILATOR ECO-CHOICE
*L Exception for Horizontal Installations:
USA INSTALLATIONS
: A non-combustible fl oor protec-
tion is recommended extending beneath the fl ue pipe when
installed with horizontal venting or under the Top Vent
Adapter with vertical installation.
CANADA INSTALLATIONS
: A non-combustible fl oor pro-
tection extending beneath the fl ue pipe is
required
with hor-
izontal venting or under the Top Vent Adapter with vertical
installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
NOTE:
•
Illustrations refl ect typical installations and are FOR DESIGN
PURPOSES ONLY.
•
I
llustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
L*
K
K
M
Use a non-combustible fl oor protector, extending beneath
appliance and to the front, sides and rear as indicated. Mea-
sure front distance “M” from the surface of the glass door.
Hearth Pad Requirements
Inches
Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
Straight Back Against Wall
Inches
Millimeters
A
Back Wall to Appliance
2
51
B
Side Wall to Appliance
14
356
Corner Installation
Inches
Millimeters
C
Walls to Appliance
2
51
Installations with
3 to 3 inch Top Vent Adapter
Vertical Installation
Inches
Millimeters
D
Back Wall to Adapter
1
25
E
Side Wall to Appliance
14
356
F
Back Wall to Appliance
6-1/4
159
Corner Installation
Inches
Millimeters
G
Walls to Appliance
2
51
Installations with
3 to 6 inch Offset Adapter
Vertical Installation
Inches
Millimeters
D
Back Wall to Adapter
3
76
E
Side Wall to Appliance
14
356
F
Back Wall to Appliance
10-3/4
274
Corner Installation
Inches
Millimeters
G
Walls to Appliance
2
51
C
C
D
E
F
G
G
A
B
B. Clearances to Combustibles (UL and ULC)
C. Hearth Pad Requirements (UL and ULC)
Fire Risk
Comply with all minimum clearances to combustibles as
specifi ed.
Failure to comply may cause house fi re.
WARNING