background image

22

B. Accessories

1. Doors

2.  Gas Inserts
3.  Gas Log Sets
4.  Gas Log Lighters
5.  Wood-burning Inserts

DFG4036 Series Glass Bi-fold Doors

(optional)

DFS4036 Series Mesh Cabinet-Style Doors

(optional)

Heatilator • Birmingham 36-B  OWNERS MANUAL • 4059-710 • Rev F • 11/25/13

Summary of Contents for BIR36-B

Page 1: ...is not followed exactly a fire or explosion may result causing property damage personal injury or death Owner s Manual Operation and Care WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Al...

Page 2: ...3 Important Safety and Operating Information A Fireplace Safety 7 1 Clear Space 7 2 Grate 8 3 Molded Brick Panel 8 4 Firescreen 8 5 Flue Damper 8 6 Glass Doors 8 7 Over Firing Your Fireplace 8 8 Chimney Fire 8 B General Operating Parts 9 1 Flue Damper 10 2 Outside Air 10 3 Glass Doors 10 C Fuel 11 1 Hardwood vs Softwood 11 2 Moisture content 11 3 Seasoning 12 4 Storing Wood 12 5 Burning Process 12...

Page 3: ...____________________________________________________ Address ____________________________________________________________ ____________________________________________________________ Phone _____________________________________________________________ E mail _____________________________________________________________ Grate Fireplace Model Serial Number Heatilator Birmingham 36 B OWNERS MANUAL 405...

Page 4: ...verage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered components is pro...

Page 5: ... Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use of abr...

Page 6: ...as logs Damper must be locked open Gas flame may generate fumes Heatilator Birmingham 36 B OWNERS MANUAL 4059 710 Rev F 11 25 13 This fireplace may be installed in sleeping rooms EX CEPT in manufactured homes If installed with a gas log set provisions for the National Fuel Gas Code must be met This fireplace has been tested and listed for use with the optional components specified in this manual T...

Page 7: ...nents Improper installation adjustment alteration service or maintenance can cause injury or property damage 1 Clear Space Combustible materials must not be stored on the hearth extension Room furnishings such as drapes curtains chairs or other combustibles must be at least 4 ft 1219 mm from the front of the fireplace Combustible materials are materials made of or sur faced with any of the followi...

Page 8: ...ed integral grate Keeps logs in place Allows proper air circulation around the fire 3 Molded Brick Panel The molded brick panel is shipped separately but required to contain heat and provide an attractive interior It will deteriorate over time and will need occasional replacement Small hairline cracks and discoloration are normal and do not affect its safety Cracks in the mortar may occur and do n...

Page 9: ...ratures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down Figure 3 2 General Operating Parts CAUTION If you expect that children may come into contact with this fireplace we recommend a barrier such as a decorative screen See your dealer ...

Page 10: ...Figure 3 3 Operating Positions of Bi fold Doors 2 Outside Air Refer to Figure 3 2 for location and operation of control The outside air kit supplies some combustion air for your fireplace It may help reduce the effects of nega tive air pressure Other methods may be required if more air is needed The outside air inlet should be in the fully opened posi tion during operation of the fireplace Close t...

Page 11: ...u can use the softwood for starting the fire giv ing off quick heat to bring the fireplace up to operating temperature Add the hardwood for slow even heat and longer burn time 2 Moisture content The majority of the problems fireplace owners expe rience are caused by trying to burn wet unseasoned wood Freshly cut wood can be as much water as it is wood having a moisture content of around 50 Imag in...

Page 12: ...od about eighteen months Notice Seasoning time may vary depending on drying conditions 4 Storing Wood Splitting wood before it is stored reduces drying time The following guideline will ensure properly seasoned wood Stack the wood to allow air to circulate freely around and through the woodpile Elevate the woodpile off the ground to allow air circulation underneath The smaller the pieces the faste...

Page 13: ...You may notice an industrial odor the first few fires This is considered normal Use well seasoned wood Open the flue damper to a fully open position Place crumpled or twisted paper under the fireplace grate Loosely arrange kindling or small pieces of wood to form a tent on the fireplace grate Pre warm the flue to establish a draft to help reduce smoke spillage during start up Hold a rolled up piec...

Page 14: ...y Sweep Confirm that termination cap remains clear and unobstructed Inspect for blockages such as bird nests leaves etc Inspect for corrosion or separation Inspect for creosote and remove as needed at least every two months during the heating season Inspect the system at the fireplace connection and at the chimney top In the event of a chimney fire Hearth Home Tech nologies recommends replacement ...

Page 15: ...ash from the firebox and extinguish all hot embers before disposal Allow the fireplace to cool completely Remove baffle and ceramic blanket from fireplace before cleaning chimney refer to Section 5 C 3 Baffle Removal and Installation Close the door tightly Remove the top of the termination cap as shown in Figure 4 1 to clean the cap and chimney The creosote or soot should be removed from the chimn...

Page 16: ...s until the fire is out and the fireplace is cold Ashes should be placed in metal container with tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until...

Page 17: ...tion Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to starting fire section Flue blockage such as birds nests or leaves in termination cap Have chimney inspected for creosote and cleaned by a certified chimney sweep Down draft or negative pressure Competition with exhaust devices Do not use exhaust fans during start up refer to negative p...

Page 18: ...s then light the paper under the kindling The heat generated from the burning rolled up newspaper should help get the draft established Still other factors can affect how well your flue system performs Neighboring structures high winds tall trees even hillsides can affect air currents around the chim ney Well designed chimney caps are available that can help Your fireplace dealer is the local expe...

Page 19: ... Outside air closed Overhead fan operating Overhanging tree Bird s nest or leaves in termination cap Structural changes in chimney area Creosote buildup in flue Strong win d s a r o u nd chimney termination Unsealed can lights Combustion air control Figure 5 1 Factory built Fireplaces Troubleshooting Heatilator Birmingham 36 B OWNERS MANUAL 4059 710 Rev F 11 25 13 ...

Page 20: ...BER 1 Damper Blade Assembly 29964 2 Damper Control 20549 3 Outside Air Collar Assembly Qty 2 req 4059 037 4 OA Door Qty 2 req 4059 049 5 Firescreen Assembly W Rod Qty 2 req 4059 053 Y 6 Screen Rod Qty 2 req 4059 512 Y Screen Rod Clips Qty 2 req 4059 111 Y 7 Firescreen Assembly 4059 054 8 Grate Assembly GR30 Y 9 Hearth Refractory SRV4059 693 Mortar 10 Lb Bucket MMMORTR Outside Air Hood Qty 2 req 40...

Page 21: ...ial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Traditional Refractory MMTB36 B 10 Left Panel SRV4059 652 11 Back Panel SRV4059 659 12 Right Panel SRV4059 653 Herringbone Refractory MMHB36 B 13 Left Panel SRV4059 656 14 Back Panel SRV4059 661 15 Right Panel SRV4059 657 Refractory Fastener Pack 4059 668 Contains 8 6 X 1...

Page 22: ... Gas Inserts 3 Gas Log Sets 4 Gas Log Lighters 5 Wood burning Inserts DFG4036 Series Glass Bi fold Doors optional DFS4036 Series Mesh Cabinet Style Doors optional Heatilator Birmingham 36 B OWNERS MANUAL 4059 710 Rev F 11 25 13 ...

Page 23: ...23 This page intentionally left blank Heatilator Birmingham 36 B OWNERS MANUAL 4059 710 Rev F 11 25 13 ...

Page 24: ...9099 6048195 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6863064 6866205 6869278 6875012 6880275 6908039 6919884 7047962 7216645 D320652 D445174 D462436 Canada 1297749 2195264 2225408 2313972 Australia 780250 780403 1418504 or other U S and...

Reviews: