Heatilator • ADI60 • 345-900EF Rev. G • 2/06
8
1
Approvals and Codes
Approval Listing and Codes
Appliance Certification
The Heatilator models discussed in this
Installers Guide
have
been tested to certification standards and listed by the
applicable laboratories.
Homologation de l’appareil
Les modèles Heatilator dont il est question dans ce
Guide
d’installation
ont été testés conformément aux normes
d’homologation et ont été approuvés par les laboratoires
compétents.
Homologations et codes
Homologations et codes
High Altitude Installations
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2,000 feet in the
U. S. A. and in Canada.
When installing this appliance at an elevation above 2,000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. or 10% for elevations
between 2000 and 4500 in Canada. If the heating value of
the gas has been reduced, these rules do not apply. To
identify the proper orifice size, check with the local gas utility.
If installing this appliance at an elevation above 4,500 feet
(in Canada), check with local authorities.
Installation à haute altitude
Les appareils à gaz homologués U.L. ont été testés et
approuvés pour être utilisés sans modification à des altitudes
comprises entre 0 et 610 mètres (0 et 2 000 pieds) aux
États-Unis et au Canada.
Si cet appareil est installé à une altitude supérieure à 610
mètres, il peut s’avérer nécessaire de réduire l’admission
du gaz en diminuant l’ouverture de l’orifice du brûleur. Le
débit calorifique doit être réduit de 4 % tous les 305 mètres
(1 000 pieds) au-dessus de 610 mètres d’altitude (2 000
pieds) aux États-Unis ou de 10 % entre 610 et 1 372 mètres
d’altitude (2 000 et 4 500 pieds) au Canada. Si le pouvoir
calorifique du gaz a été réduit, ces règles ne s’appliquent
pas. Pour connaître l’ouverture de l’orifice qui convient,
consultez le service local de distribution de gaz.
Si cet appareil est installé à une altitude supérieure à 1.370
mètres (au Canada), consultez les autorités locales.
Installation Codes
The appliance installation must conform to local codes.
Before installing the appliance, consult the local building
code agency to ensure that you are in compliance with all
applicable codes, including permits and inspections.
In the absence of local codes, the appliance installation must
conform to the National Fuel Gas Code ANSI Z223.1 (in the
United States) or the CAN/CGA-B149 Installation Codes (in
Canada). The appliance must be electrically grounded in
accordance with local codes or, in the absence of local codes
with the National Electric Code ANSI/NFPA No. 70 (in the
United States), or to the CSA C22.1 Canadian Electric Code
(in Canada).
These models may be installed in a bedroom or bed-sitting
room in the U.S.A. and Canada.
Codes d’installation
L’installation de l’appareil doit être conforme aux codes
locaux. Avant d’installer l’appareil, consultez les autorités
locales en matière de codes de construction afin de vous
assurer que vous respectez tous les codes en vigueur, y
compris les permis de construire et les inspections.
En l’absence de codes locaux, l’installation de l’appareil doit
être conforme au code américain
National Fuel Gas Code
ANSI Z223.1 (aux États-Unis) ou aux Codes des installations
CAN/CGA-B149 (au Canada). L’appareil doit être muni d’un
fil de terre conformément aux codes locaux ou, en l’absence
de codes locaux, au code américain
National Electric Code
ANSI/NFPA n°70 (aux États-Unis) ou au Code électrique
canadien CSA C22.1 (au Canada).
Ces modèles peuvent être installés dans une chambre à
coucher ou une chambre-salon aux États-Unis et au Canada.
CERTIFICATION STANDARD
MODEL
ADI60
LABORATORY
Underwriters Laboratories
TYPE
Direct Vent Gas Fireplace Heater
STANDARD
ANSI Z21.88•CSA2.33•UL307B
NORME D’HOMOLOGATION
MODÈLE
ADI60
LABORATOIRE
Underwriters Laboratories
TYPE
Cassette de cheminée à gaz à
système d’évacuation directe
NORMES
ANSI Z21.88•CSA2.33•UL307B